6

 

2. GENERAL

 

SPECIFICATIONS

 

Load

 

capacity

 

750

 

lb

 

(340

 

kg)

 

Maximum

 

travel

 

M2LIFT-40:

 

42”

 

(1067

 

mm)

 

M2LIFT-60:

 

62”

 

(1575

 

mm)

 

M2LIFT-75:

 

77”

 

(1956

 

mm)

 

Minimum

 

travel

 

15.5”

 

(394

 

mm)

 

Levels

 

serviced

 

2

 

Nominal

 

speed

 

9

 

ft/min

 

(0.046

 

m/s)

 

Daily

 

cycle

 

Normal:

 

10

 

Heavy:

 

25

 

Excessive:

 

40

 

Maximum

 

starts

 

in

 

1

 

hour

 

on

 

standard

 

installation:

 

5

 

Platform

 

size

 

37

 

1/8” x

 

54

 

1/8” (9443

 

mm

 

x

 

1375

 

mm)

 

Side

 

wall

 

height

 

42”

 

(1067

 

mm)

 

Access

 

Front/rear

 

access

 

(type

 

2

 

cab)

 

Power

 

supply

 

120

 

VAC,

 

15A,

 

60

 

Hz,

 

single

 

phase

 

Drive

 

system

 

Direct

 

drive

 

gear

 

Chain

 

suspension

 

Motor

 

24

 

VDC,

 

1.3

 

HP,

 

geared

 

Controller

 

LUT125

 

PCB

 

Finish

 

Electrostatic

 

powder

 

coat

 

paint

 

on

 

all

 

metallic

 

surfaces

 

and

 

vacuumed

 

formed

 

plastics

 

Standard

 

features

 

24VDC

 

operation

 

Wireless

 

call/send

 

stations

 

at

 

landings

 

Constant-pressure

 

type

 

buttons

 

Operating

 

control

 

buttons

 

on

 

platform

 

Automatic

 

battery

 

recharging

 

system

 

(115

 

VAC)

 

Low-voltage

 

controls

 

Limit

 

switches

 

Non-skid

 

platform

 

surface

 

Automatic

 

access

 

ramp

 

Emergency

 

stop

 

button

 

(E-stop

 

on

 

COP)

 

and

 

alarm

 

Pit

 

switch

 

(E-stop

 

on

 

tower)

 

Safety

 

underpan

 

Motor

 

safety

 

brake

 

Battery

 

lowering

 

Outdoor

 

package

 

M2LIFT

 

Owner’s

 

Manual

 

Part

 

No.

 

001103,

 

10-m08-2021

 

Содержание M2LIFT

Страница 1: ...M2Lift Vertical Platform Lift Owner s Manual ...

Страница 2: ...nce schedule Refer to this owner s manual for unit description setup operating instructions and a maintenance schedule for your Lift Upon completion of installation the Savaria mechanic must provide you with the information for the box below and ensure it is recorded in this owner s manual In addition either you or the Savaria mechanic must keep any service and or maintenance records in the Mainte...

Страница 3: ...RIPTION 5 2 GENERAL SPECIFICATIONS 6 3 OPERATION 7 Attendant Operation 7 Operating from the COP Controls 7 Operating from the Landing Station Controls 8 4 ADDITIONAL FEATURES 10 Safety Underpan 10 Gate Lock 11 Safety Brake 11 Emergency Stop Button 11 Battery Lowering 11 5 MAINTENANCE 12 Maintenance Schedule 12 Operator Troubleshooting 14 Maintenance Record 15 Part No 001103 10 m08 2021 M2LIFT Owne...

Страница 4: ...d personnelperform maintenanceand service on the unit When replacing parts be surethat only genuine Savaria parts are used This unit is intended for use by a mature person who understands its proper operation as set out in this manual WARNING At no time shouldchildren underthe age of 16 use the lift while unsupervised Prior to operation make sure that All doors and gates are locked and secure All ...

Страница 5: ...LIFT Figure 1 Car operating Tower rail cap panel COP Landing gate COP side wall Tower Landing sill Opposite side wall Access ramp Fascia Non skid platform panel Motor cover Pit switch Safety underpan Base support legs Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Страница 6: ... phase Drive system Direct drive gear Chain suspension Motor 24 VDC 1 3 HP geared Controller LUT125 PCB Finish Electrostatic powder coat paint on all metallic surfaces and vacuumed formed plastics Standard features 24VDC operation Wireless call send stations at landings Constant pressure type buttons Operating control buttons on platform Automatic battery recharging system 115 VAC Low voltage cont...

Страница 7: ...if the lift is unenclosed The attendant shall have full view of the floor area under the lift and of the rider at all times If the lift is enclosed the lift can be operated from the upper landing provided the operator has a view of the rider at all times During attendant operation the car directional controls must not be operational Operating from the COP Controls Figure 2 shows the car operating ...

Страница 8: ... the unit is not in operation 5 Pressing the Emergency Stop button during travel will stop the lift immediately and activate the alarm The Emergency Stop overrides the landing station controls Pull the Emergency Stop out to return the lift to normal operation 6 If the gate is locked at a landing for more than 10 seconds you can press the Up button to unlock the gate Operating from the Landing Stat...

Страница 9: ... open 3 When the lift reaches the landing the door will unlock automatically If you need to re open the door after the delay turn the key on and press the call Up button again to unlock the door 4 To prevent unauthorized useof the lift takethe key outwhen the unit is not in operation Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Страница 10: ... Figure 4 is located under the platform The underpan has sensors that detect any obstacles and stop the downward travel of the lift This is optional on enclosed units and required on open hoistways Figure 4 Safety Underpan M2LIFT Owner s Manual Part No 001103 10 m08 2021 ...

Страница 11: ...ey a half turn counter clockwise to remove it from the lock DO NOT open the gate if there is any chance of falling from the platform Safety Brake EY 0 The motor Safety Brake stops the platform in the event of a chain failure During normal operation the chain tension keeps the brake mechanism up so the brake cam does not interfere with the tower guide rail If a chain failure occurs the brake mechan...

Страница 12: ...ft is safely shored when working under the platform Maintenance Schedule Verification Frequency Verify general operation of the lift Every 2 months Verify correct operation of the underpan sensors Every 2 months Verify correct operation of the emergency stop Every 2 months Verify correct operation of the gate lock contacts The lift should not run unless the gate is closed and locked Every 2 months...

Страница 13: ...stem The tensioners must be tight Every 6 months Verify that all hardware is tightened Every 6 months Check the safety brake Every 6 months Check the rollers function and wear Every 6 months Ensure that all filler panels are securely fastened in the gate Every 6 months Part No 001103 10 m08 2021 M2LIFT Owner s Manual ...

Страница 14: ...he pan is not stuck in the activated position Platform comes down but does not go up Check that the power cord is plugged in Platform does not move Check that the key is ON Check that the gate is closed Check to see if the Emergency Stop buttons on the COP and tower are pushed in they must be pulled out for normal operation If the platform is at the top landing check the underpan sensors as descri...

Страница 15: ...Maintenance Record Date Time Reason for call Comments Dealer ...

Страница 16: ... service or questions about this product please contact your installing dealer Dealer Name Dealer Phone Authorized Savaria Dealer Savaria Concord Lifts Inc 2 Walker Drive Brampton ON L6T 5E1 Canada savaria com Part No 001103 2021 Savaria Corporation ...

Отзывы: