14
Operator Troubleshooting
The
following
table
lists
potential
problems
and
their
possible
solutions.
If
the
problem
persists,
contact
your
Authorized
Dealer.
Potential
Problem
Possible
Solution
Platform
goes
up
but
does
not
come
down
Check
the
underpan
sensors.
Pull
down
on
the
underpan
to
ensure
the
pan
is
not
stuck
in
the
activated
position.
Platform
comes
down
but
does
not
go
up
Check
that
the
power
cord
is
plugged
in.
Platform
does
not
move
Check
that
the
key
is
ON.
Check
that
the
gate
is
closed.
Check
to
see
if
the
Emergency
Stop
buttons
(on
the
COP
and
tower)
are
pushed
in;
they
must
be
pulled
out
for
normal
operation.
If
the
platform
is
at
the
top
landing,
check
the
underpan
sensors
as
described
above.
Check
that
the
power
cord
is
plugged
in.
M2LIFT
Owner’s
Manual
Part
No.
001103,
10-m08-2021