Savant WPX LV06 Series Скачать руководство пользователя страница 3

Wireless Configurable Keypad for DMX Control - QRG

3     of     5

45 Perseverance Way, Hyannis MA 02601.

Copyright© 2021 Savant Systems, Inc. |  009-2075-00 |  211015

Savant.com

  |  508.683.2500

DMX-DRIVER3

No Connection
No Connection
No Connection
No Connection
No Connection

D+ (data)
D- (data)

Ground

Pin 3
Pin 4
Pin 5
Pin 6

Pin 7
Pin 8

Pin 2

Pin 1

WPX/WIX-xxLV06

Back Panel

-

+

D+

D-

120/240V AC

OUTPUT

INPUT

Blue = Neutral
Green w/Yellow Stripe = Gnd

black = V-

+24V DC Input

red = V+

Brown = Gnd

HLG-240H-24

POWER SUPPLY

GND

DMX Input

DMX in/out

1

1

8

8

DMX in/out

D-

D+

D-

D+

W2/WW

W1/CW

B/WW

G/CW

R/WW

V+

V+

V-

V-

+

DMX-DRIVER3

Wiring for the 

WRGB LED 

Strip shown

DC +24V
G
R
B
W

24V DC Gnd
24V DC Input

D+ (data)
D- (data)

Black
Red

Blue

Yellow

Station Pigtail

Length - 5 

½

 inches

Gauge - #22 AWG stranded.

SHA-W1000

CAT-5e/6

Pinout for DMX Ports

CAT-5e/6

24V DC

DMX IN

DMX OUT 

P3

ON

OFF

DMX IN

DMX OUT 

P3

ON

OFF

Set the Dipswitch on the 

last fixture in the chain to ON.

(End of Line Terminator)

Daisy-chain connections 

between lighting fixtures.

DMX Out 

 DMX In

DMX 

LIGHT 

FIXTURE 1 

DMX 

LIGHT 

FIXTURE 2 

RJ-45 Connector

 

(Gold pins facing up)

Pin 1 Pin 8

Additional Information

 

Savant recommends using the SHA-W1000 cable when making connections between the DMX-DRIVER3 and DMX keypad. Shown 

in the diagram above is the SHA-W1000 cable with the recommended wire colors and connections.

 

Savant recommends the HLG-240H-24 power supply shown in the diagram. This transformer can supply the 24V DC needed to 

power the DMX keypad and LED driver. However, other power supplies such as the SHA-POWSINGLE transformer or the +/- ports 

on the SKL-3040/1010 keypad power and control module can be used.

 

See the 

Maximum Wiring

 section in the table above when making connections between the DMX Keypad and DMX Driver.

 

Up to 32 DMX devices are supported on each DMX keypad. This includes the combination of drivers, lighting fixtures, and LED 

strips. Do not exceed 32 RDM devices as listed in the RDM tab of the OLA server. 

 

Maximum distance of the DMX cable is 1600 feet. This is the total distance daisy-chained through all fixtures.

 

Set the dipswitch on the last fixture in the chain to ON. The last fixture is regarded as an end of line terminator.

 

Do not run DMX signaling in the same conduit as the high voltage AC lines.

 

Fixtures/loads will not illuminate when there is no DMX signal present

 

See the DMX Keypad Deployment Guide on the 

Savant Customer Community 

for additional wiring diagrams.

The image below shows the DMX-DRIVER3 providing control to both an LED strip and a USAI DMX lighting fixture. Use the diagram 

below for reference when connecting the various type loads.