background image

Wireless Keypad Auxiliary Control  |  009-1759-05

2     of     3

45 Perseverance Way, Hyannis MA 02601

Copyright © 2020 Savant Systems, Inc.  | 201006

Savant.com

  | 508.683.2500

1.  At the main breaker panel, switch off the breaker that supplies power to the circuit.
2.  Unscrew the wall plate and remove it. Using a 120V AC tester, verify the power was removed.
3.  Unscrew the two 6-32 flat head screws and remove the existing toggle/rocker switch.
4.  Disconnect and label each wire as they are removed from the current device. Labeling the wires ensures they will be installed onto 

the new device correctly, primarily if the circuit employs a 3-way configuration.

5.  Using the supplied wire nuts or an approved alternative, connect the in-wall wires removed from step 4 above to the leads coming 

from the new Savant Auxiliary Control keypad. See the 

Wiring Diagrams

 or 

Rear Panel

 sections for more information. 

6.  Insert the Auxiliary Control into the electrical switch box and secure it with the supplied 6-32 flat head screws. DO NOT use a 

powered screwdriver. A powered screwdriver can over tighten the screws.

7.  Install the wall plate adapter. When installing, ensure the 

adapter completely covers the metal yoke.

8.  From the main breaker panel, switch on the circuit breaker 

that was switched off in step 1 above.

9.  To test:

 

If the Auxiliary Control is wired to a Savant wireless key-

pad switch, press the top button and observe the load 

switches On. Press the lower button and observe the 

load switches Off.

NOTE

: The test above assumes that the Auxiliary Control is 

wired to a previously tested and functioning Savant 

dimmer or switch. 

When combining more than one keypad into a multi-ganged electrical box, for the devices to fit, it may be necessary to remove the 

tabs from either the left, right, or both sides of the keypad. Examples of 2, 3, and 4-gang scenarios are shown below.

 

Tabs are removed from both sides of any devices positioned on the inside of an electrical box.

 

Tabs are NOT removed from outside edges of the devices positioned at the outside ends of each electrical box.

Wall Plate

Adapter

Wall Plate

Electrical

Switch Box

Mounting

Screws

Wall Plate and Adapter

sold separately

Electrician Removal/Installation

Multi-Gang Installations

 ELECTRIC SHOCK! 

The 120V AC, 60 Hz source power poses an electrical shock hazard that has the potential to cause serious 

injury to installers and end users.

 IMPORTANT NOTES!

 

A licensed electrician is required to install any of the Savant wireless lighting devices. Isolate and turn off power at the main 

breaker panel prior to installing any electrical devices.

 

Use #14 AWG or larger solid copper wires (80°C) for supply, neutral, and ground connections. Strip wires to 

 inch (16 mm).