SAV 531.01
3 TECHNICAL SPECIFICATIONS
Influence of the material in the holding force
High magnetic flux values and therefore the highest holding forces can be achieved in technically pure iron. In
practical application, a number of materials with different magnetic characteristics are used.
In addition to this, heat treatments influence the magnetising capacity of materials as this is altered by the physical
structure of the materials. Hardened materials have poorer conduction of the magnetic flux.
100%
53%
58%
ho
ld
ing f
or
ce i
n %
tool steel,
annealed
tool steel,
hardened
tool steel,
tempered
0
10
20
30
40
50
60
70
80
90
100
ho
ld
ing f
or
ce i
n %
unmagnetised alloy component in %
0
20
40
60
80
100
0
10
20
30
Fig. 4: Influence of the unmagnetised alloy component
on the holding forces
Fig. 5: Influence of the heat treatment condition on the
holding forces (example)
Short designation as per DIN
Material no.
Max. non-magnetic alloy component
Heat treatment
Holding force
Pure iron
Fe
–
0.00%
soft
100 %
Construction steel
St37-2
1.0037
–
soft
95 %
St52-3 N
1.0570
–
soft
93 %
St50-2
1.0050
–
soft
75 %
Case-hardened steel
C10
1.0301
1.22%
soft
93 %
C15
1.0401
1.27%
soft
93 %
17CrNiMo6
1.6587
5.43%
soft
72 %
16MnCr5
1.7131
3.06%
soft
83 %
20MnCr5
1.7149
3.40%
soft
82 %
C10
1.0301
1.22%
case-hardened
48 %
C15
1.0401
1.27%
case-hardened
48 %
17CrNiMo6
1.6587
5.43%
case-hardened
38 %
16MnCr5
1.7131
3.06%
case-hardened
43 %
20MnCr5
1.7149
3.40%
case-hardened
42 %
Nitriding steel
34CrAl6
1.8504
4.29%
untreated
77 %
31CrMoV9
1.8519
4.65%
untreated
76 %
34CrAlNi7
1.8550
5.93%
untreated
70 %
39CrMoV13-9
1.8523
6.44%
untreated
68 %
34CrAl6
1.8504
4.29%
nitrided
50 %
Содержание NEO 1200