background image

   

                 TC-BA-e-1712 

 

 

 

GB 

SAUTER TC  

Version 1.2  08/2017 

Instruction Manual 
Digital Coating Thickness Gauge

 

 

 

 

Thank you for buying a SAUTER digital Coating Thickness Gauge. We hope you are 
pleased with your high quality Thickness Gauge with its big functional range.  
If you have any queries, wishes or helpful suggestions, do not hesitate to call our 
service number. 
 

Models available: 
- TC 1250-0.1 F 
- TC 1250-0.1 N 
- TC 1250-0.1 FN

 

- TC_car 1250-0.1FN (separate instruction manual available) 
 

Summarize: 

 

1

 

Features .......................................................................................................... 3

 

2

 

Specifications ................................................................................................ 3

 

3

 

Front Panel description ................................................................................. 5

 

4

 

Measuring procedure .................................................................................... 5

 

5

 

Zero- Adjustment (Calibration) ..................................................................... 6

 

6

 

Battery replacement ...................................................................................... 7

 

7

 

Adjustment foils ............................................................................................. 7

 

8

 

General advise ............................................................................................... 7

 

9

 

How to restore Factory Settings ................................................................... 7

 

10

 

Notes ............................................................................................................... 8

 

 
 
 
 
 
 
 
 
 
 
 

Содержание TC 1250-0.1 F

Страница 1: ...n E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Coating Thickness Gauge SAUTER TC Version 1 2 08 2017 GB Illustration TC 1250 0 1FN TC BA e 1712 PROFESSIONAL MEASURING ...

Страница 2: ...ge If you have any queries wishes or helpful suggestions do not hesitate to call our service number Models available TC 1250 0 1 F TC 1250 0 1 N TC 1250 0 1 FN TC_car 1250 0 1FN separate instruction manual available Summarize 1 Features 3 2 Specifications 3 3 Front Panel description 5 4 Measuring procedure 5 5 Zero Adjustment Calibration 6 6 Battery replacement 7 7 Adjustment foils 7 8 General adv...

Страница 3: ...d on magnetic metals e g steel iron nickel etc The N sensor measures the thickness of non magnetic coatings on non magnetic metals It is used on anodizing varnish paint enamel plastic coatings powder etc It can be applied on non magnetic materials like aluminium brass stainless steel etc The N sensor measures the thickness of non magnetic coatings on non magnetic metals It is used on anodization v...

Страница 4: ...V AAA UM 4 battery Operating conditions Temperature 0 to 50 C Humidity less than 80 Dimensions 127 x 67 x 28mm 5 0 x 2 6 x 1 1Inch Weight about 81g batteries not included Scope of delivery Carrying case Instruction manual According to types 1 Incorporated sensor at F model TC 1250 0 1 F with button F N 2 Incorporated sensor at N model TC 1250 0 1 N with button F N 3 Incorporated sensor at FN model...

Страница 5: ...ymbol Fe F for magnetic metals or NFe N for non magnetic metals which is indicated on the display It switches to the automatic measurement mode which also correctly identifies the zeroing plate or any other base material b The sensor 3 1 has to be placed onto a coating layer to be measured The reading on the display is the thickness of the coating layer This can be corrected by pressing the Plus k...

Страница 6: ...s the Power key 3 6 5 Zero Adjustment Calibration a Zero adjustment for Fe F and NFe should be carried out separately The Zero plate of iron has to be chosen if Fe is displayed and zero plate of alumi num has to be chosen if NFe is displayed Sensor 3 1 has to be placed carefully onto the appropriate base plate or another un coated base material The Zero key 3 3 has to be pressed without lifting th...

Страница 7: ...ise a The instrument should always be calibrated on the uncoated base material to be measured instead of the base plate included in the delivery Then accuracy is more precise right from the start b Sensors will eventually wear off Life of the sensor will depend on the number of measurements taken and how abrasive the coating is The change of a sensor should only be performed by qualified persons 9...

Страница 8: ...y be adjusted by professional persons Generally said The bigger the value of Ln the smaller the reading on the display for the same coat ing thickness Only a small change of the value of LN causes a big change in the reading of the upper measurement range at 500µm 20 mil The value of LN has to be adjusted as follows By pressing the Power key It lasts about 11 seconds from starting to press this ke...

Отзывы: