General notes

Subject to errors and technical changes. All statements and data herein represent our best knowledge at date of publication. They are only meant to inform about 
our products and their application potential, but do not imply any warranty as to certain product characteristics. Since the devices are used under a wide range 
of different conditions and loads beyond our control, their particular suitability must be verified by each customer and/or end user themselves. Existing property 
rights must be observed. We warrant the faultless quality of our products as stated in our General Terms and Conditions.

–  This device may only be used in pollutant-free non-precipitating air without above-atmospheric or below-atmospheric pressure  

at the sensor  element. 

– Dust and pollution falsify measurement results and are to be avoided.  

Slight pollution and dust sediments can be removed by using compressed air. 

–  Touching the humidity element is under any circumstances to be avoided, as that would result in considerable mismeasurements.
–  In case of pollution, we recommend cleaning and recalibration in the factory.
–  In any case, the sensor must not get in contact with chemicals or other cleaning agents.
–  The relative humidity of 0 ...100 % is indicated by an output signal of 0 -10 V. 

The device operating range covers 10.0 ... 99.9 % r. H. Outside of that range, mismeasurements or increased deviations may occur.

–  When several sensors (0  -10 V) are connected to one voltage supply of 24 V  AC,  

correct polarity must be regarded as otherwise the  alternating  voltage source may be short-circuited. 

–  The voltage outputs are short-circuit proof. Applying overvoltage or voltage supply to the voltage output will destroy the device.
–  If this device is operated beyond the specified range, all warranty claims are forfeited.

In addition, the following points are to be observed:

–  These instructions must be read before installation and putting in operation and all notes provided therein are to be  regarded!
–  Devices must only be connected to safety extra-low voltage and under dead-voltage condition.  

To avoid damages and errors at the device (e.g. by voltage induction) shielded cables are to be used,  
laying parallel with current-carrying lines is to be avoided, and EMC directives are to be observed.

–  This device shall only be used for its intended purpose. Respective safety regulations issued by the states, their  control authorities,  

the TÜV and the local energy supply company must be observed. The purchaser has to adhere to the building and safety regulations and has to 
prevent perils of any kind.

–  No warranties or liabilities will be assumed for defects and damages arising from improper use of this device.
–  Consequential damages caused by a fault in this device are excluded from warranty or liability.
–  These devices must be installed and commissioned by authorised specialists.
–  The technical data and connecting conditions of the mounting and operating instructions delivered together with the device are exclusively valid. 

Deviations from the catalogue representation are not explicitly mentioned and are possible in terms of technical progress and continuous 
improvement of our products.

–  In case of any modifications made by the user, all warranty claims are forfeited.
–  This device must not be installed close to heat sources (e.g. radiators) or be exposed to their heat flow.  

Direct sun irradiation or heat  irradiation by similar sources (powerful lamps, halogen spotlights) must absolutely be avoided.

–  Operating this device close to other devices that do not comply with EMC directives may influence functionality.
–  This device must not be used for monitoring applications, which serve the purpose of protecting persons against hazards or injury,  

or as an EMERGENCY STOP switch for systems or machinery, or for any other similar safety-relevant purposes.

–  Dimensions of enclosures or enclosure accessories may show slight tolerances on the specifications provided in these instructions.
–  Modifications of these records are not permitted.
–  In case of a complaint, only complete devices returned in original packing will be accepted.

Notes on commissioning: 

This device was calibrated, adjusted and tested under standardised conditions. When operating under deviating conditions,  
we recommend performing an initial manual adjustment on-site during commissioning and subsequently at regular intervals. 

Commissioning is mandatory and may only be performed by qualified personnel!  
These instructions must be read before installation and commissioning and all notes provided therein are to be regarded!

Содержание EGH130F931

Страница 1: ...urf hler 2 Aufputz kalibrierf hig mit aktivem Ausgang G Operating Instructions Mounting Installation Room humidity and temperature sensors 2 on wall calibratable with active output F Notice d instruct...

Страница 2: ...n the groove at centre press down and lift up the bottom frame slightly Pull top cover for ward and hold it Pour ouvrir le bo tier placer le tournevis 2 0 au centre de l encoche pousser vers le bas et...

Страница 3: ...ich TECHNISCHE DATEN Spannungsversorgung 24 V AC 20 und 15 36 V DC Lastwiderstand RL 5 kOhm Leistungsaufnahme 1 1 VA 24 V DC 2 2 VA 24 V AC Sensoren digitaler Feuchtesensor mit integriertem Temperatur...

Страница 4: ...1 0 10 2 0 15 3 0 20 4 0 25 5 0 30 6 0 35 7 0 40 8 0 45 9 0 50 10 0 Anschlussbild Ausgang 0 10 V D EGH130F931 Rev 2021 V23 1 2 3 4 230V AC 24V AC DC SPS PC UB 24V AC DC Ausgang Feuchte r H 0 10V Ausg...

Страница 5: ...g ge messen Wird dieses Ger t mit DC Versorgungsspannung betrieben ist der Betriebsspannungseingang UB f r 15 36 V DC Einspeisung und UB bzw GND als Masseleitung zu verwenden Werden mehrere Ger te von...

Страница 6: ...verlegung zu stromf hrenden Leitungen zu vermeiden und die EMV Richtlinien zu beachten Dieses Ger t ist nur f r den angegebenen Verwendungszweck zu nutzen dabei sind die entsprechenden Sicherheitsvors...

Страница 7: ...ble TECHNICAL DATA Power supply 24 V AC 20 and 15 36 V DC Load resistance RL 5 kOhm Power consumption 1 1 VA 24 V DC 2 2 VA 24 V AC Sensors digital humidity sensor with integrated temperature sensor s...

Страница 8: ...C C UA in V 0 0 0 5 1 0 10 2 0 15 3 0 20 4 0 25 5 0 30 6 0 35 7 0 40 8 0 45 9 0 50 10 0 Connecting diagram Output 0 10 V 4 wire connection Schematic diagram 1 2 3 4 230V AC 24V AC DC PLC PC UB 24V AC...

Страница 9: ...ge supply it is to be ensured that all positive operating voltage input terminals of the field devices are connected with each other and all negative operating voltage input terminals reference potent...

Страница 10: ...rallel with current carrying lines is to be avoided and EMC directives are to be observed This device shall only be used for its intended purpose Respective safety regulations issued by the states the...

Страница 11: ...ustage fin peut tre effectu par l utilisateur CARACT RISTIQUES TECHNIQUES Alimentation en tension 24 V ca 20 15 36 V cc R sistance de charge RL 5 kOhm Puissance absorb e 1 1 VA 24 V cc 2 2 VA 24 V ca...

Страница 12: ...mesure 0 50 C C UA en V 0 0 0 5 1 0 10 2 0 15 3 0 20 4 0 25 5 0 30 6 0 35 7 0 40 8 0 45 9 0 50 10 0 Sch ma de raccordement Sortie 0 10 V Raccordement 4 fils Sch ma de raccordement 1 2 3 4 230V AC 24V...

Страница 13: ...ls sont aliment s en 24V ca il faut veiller ce que toutes les entr es de tension positives des appareils de terrain soient reli es entre elles de m me que toutes les entr es de tension n gatives poten...

Страница 14: ...oser les c bles de sondes en parall le avec des c bles de puissance les directives CEM sont respecter Cet appareil ne doit tre utilis que pour l usage qui est indiqu en respectant les r gles de s curi...

Страница 15: ...nsione di alimentazione 24 V AC 20 e 15 36 V DC Carico ammissibile RL 5 kOhm Potenza assorbita 1 1 VA 24 V DC 2 2 VA 24 V AC Sensori sensore di umidit digitale con sensore di temperatura integrato bas...

Страница 16: ...15 3 0 20 4 0 25 5 0 30 6 0 35 7 0 40 8 0 45 9 0 50 10 0 I EGH130F931 Rev 2021 V23 Schema di collegamento Uscita 0 10 V Collegamento a 4 conduttori Schema di comando 1 2 3 4 230V AC 24V AC DC PLC PC...

Страница 17: ...r l alimentazione 15 36 V DC e l ingresso UB o GND per la terra Quando pi dispositivi sono alimentati da un unica alimentazione con ten sione 24 V AC necessario assicurarsi che tutti i terminali di in...

Страница 18: ...zare cavi schermati evitare la posa in parallelo delle linee conduttrici di corrente e rispettare le norme di compatibilit elettromagnetica Utilizzare questo apparecchio esclusivamente allo scopo indi...

Отзывы: