![Saunier Duval ThemaPLUS CONDENS F 30 E Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/saunier-duval/themaplus-condens-f-30-e/themaplus-condens-f-30-e_instructions-for-use-installation-and-servicing_1202911044.webp)
Installation and servicing instructions strictly reserved for qualifi
ed gas installers
43
Legend
1
Automatic air vent
2
Heating pump retaining screw
3
Pump
4
Discharge pipe
5
Flow sensor retaining clip
6
Flow sensor
7
Flow sensor retaining clip
8
Cold water filter retaining clip
9
Cold water filter
10 Filling tap
11 Filling pipe retaining clip
12 Filling pipe retaining clip
13 Flow sensor connector
14 “Foaming” filter retaining clip
15 “Foaming” filter
16 Discharge pipe retaining clip
17 DHW exchanger retaining screw
18 Heating safety valve retaining clip
19 Discharge valve
20 Heating safety valve
21 Filling tap
22 Heating pressure sensor retaining clip
23 Discharge retaining clip
24 Three-way valve
25 DHW safety valve retaining clip
26 DHW safety valve
27 DHW exchanger
28 Three-way valve connector
29 Heating pressure sensor connector
30 Heating pressure sensor
15.1.1 Pump
Unscrew the pump’s 4 retaining screws
(2).
Remove the pump motor (3).
Fit the new pump motor by repeating
the operations in reverse.
15.1.2 DHW exchanger
Remove the two retaining screws (17)
accessible from the front of the boiler.
Remove the DHW exchanger (27).
Fit the new DHW exchanger by
repeating the operations in reverse.
Check the assembly direction: the word
“TOP” printed on the exchanger edge
(27) must be positioned towards the
top.
15.1.3 Flow sensor
Remove the retaining clip from the
filling pipe (12), and pivot the tap and
the filling pipe.
Disconnect the connector (13) located
under the flow sensor.
Remove the clips (5) and (7).
•
•
•
•
•
•
•
•
•
•
Unscrew the cold water inlet joint under
the boiler.
Remove the flow sensor (6).
Fit the new flow sensor by repeating the
operations in reverse.
15.1.4 Heating pressure sensor
Remove the retaining clip (22) from the
heating pressure sensor.
Disconnect the connector (29).
Remove the heating pressure sensor
(30).
Fit the new heating pressure sensor by
repeating the operations in reverse.
15.1.5 Heating safety valve
Release the heating safety valve
retaining clip (18).
Remove the heating safety valve (20).
Fit the new heating safety valve by
repeating the operations in reverse.
15.1.6 Three-way valve
Disconnect the 3-way valve connector
(28).
•
•
•
•
•
•
•
•
•
•
•
Содержание ThemaPLUS CONDENS F 30 E
Страница 6: ...5 Instructions for Use ...
Страница 15: ...14 2 3 Block diagram 34 ...
Страница 27: ...26 5 9 Wiring diagram 1 2 3 4 5 6 7 11 9 8 10 12 13 14 15 16 17 18 ...
Страница 36: ...Installation and servicing instructions strictly reserved for qualified gas installers 35 ...
Страница 39: ...38 14 4 Hydraulic block TOP 1 30 29 28 27 24 23 22 21 18 20 19 17 16 14 15 2 4 3 5 6 7 8 9 10 11 12 13 25 26 ...
Страница 50: ...Installation and servicing instructions strictly reserved for qualified gas installers 49 ...
Страница 53: ......