16
4.1 Safety instructions
If the gas pressure at the input of the
appliance is outside the range specified,
you shall not start the appliance. If the
cause of the problem cannot be found
nor solved, please contact the Gas Utility
company.
Warning! Incorrect installation can cause
electric shock or appliance damage.
When making the connections, locate
the sealing washers properly so as to
avoid any gas or water leakage.
Never use a wire brush or stiff-bristle
scrubbing brush to clean the heat
exchanger as this could damage the
appliance.
Under no circumstances must the User
interfere with or adjust sealed parts.
Under Section 6 of The Health and
Safety at Work Act 1974, we are required
to provide information on substances
hazardous to health.
The adhesives and sealants used in this
appliance are cured and give no known
hazard in this state.
In the event of the appliance overheating
the safety devices will cause a safety
shutdown. If this happens, call your
installation/servicing company.
Warning! This appliance must be
earthed. This appliance must be wired in
accordance with these instructions. Any
fault arising from incorrect wiring cannot
be put right under the terms of the Saunier
Duval guarantee.
The following safety instructions must
be imperatively followed during the
maintenance and the replacement of
spare parts.
Stop the appliance (see chapter
“Deactivation” of the Instructions for
use).
-
-
-
•
Disconnect the appliance from the
mains power supply with the socket or
the double-pole switch (with a minimum
gap of 3mm for both poles).
Turn off the gas control valve.
Close the shut off valves located on the
connection sockets.
Drain the appliance when you want
to change the hydraulic parts of the
appliance.
Let the appliance cool down before
undertaking any maintenance
operation.
Protect all the electrical components
from water when you achieve any
operations.
Use only new O-rings and gaskets.
After having completed work on gas
carrying components, check their
tightness.
When the replacement work is
compleated, perform an operation test
of the replaced parts and the appliance.
4.2 Regulations
When installing and commissioning the
appliance, the regulations below shall be
observed in their current version:
In your own interests and that of safety, it
is the Law that ALL gas appliances must
be installed by a competent person only,
in accordance with the current issue of the
following regulations.
In GB the installation of the appliance
must be carried out by a competent
person as described in the following
regulations:
The manufacturer’s instructions
supplied.
The Gas Safety (Installation and Use)
Regulations.
•
•
•
•
•
•
•
•
•
-
-
Содержание ThemaPLUS CONDENS F 30 E
Страница 6: ...5 Instructions for Use ...
Страница 15: ...14 2 3 Block diagram 34 ...
Страница 27: ...26 5 9 Wiring diagram 1 2 3 4 5 6 7 11 9 8 10 12 13 14 15 16 17 18 ...
Страница 36: ...Installation and servicing instructions strictly reserved for qualified gas installers 35 ...
Страница 39: ...38 14 4 Hydraulic block TOP 1 30 29 28 27 24 23 22 21 18 20 19 17 16 14 15 2 4 3 5 6 7 8 9 10 11 12 13 25 26 ...
Страница 50: ...Installation and servicing instructions strictly reserved for qualified gas installers 49 ...
Страница 53: ......