1 Technical Data
Heating
F24E PLUS F30E PLUS
Heat input (max) NET Q
25,9 kW
32,6 kW
88,370 BTU/H
111,231 BTU/H
Heat input (min) NET Q
12,3 kW
12,5 kW
41,967 BTU/H
42,650 BTU/H
Heat output (max) GROSS P
23,6 kW
29,6 kW
80,523 BTU/H
100,995 BTU/H
Heat output (min) GROSS P
10,6 kW
10,3 kW
31,731 BTU/H
35,144 BTU/H
Efficiency - Sedbuk D
78,3%
79,6%
Maximum heating temperature
87
°
C
87
°
C
Expansion vessel effective capacity
6,5 l
8 l
Expansion vessel charge pressure
0,5 bar
0,5 bar
Maximum system capacity at 75
°
C
125 l
156 l
RED Safety valve,
maximum service pressure 3 bar
3 bar
Combustion
F24E PLUS F30E PLUS
Products outlet diameter
60 mm
60 mm
Fresh air inlet diameter
100 mm
100 mm
Combustion products values
CO (24 ppm)
CO (40 ppm)
CO2 (6,9%)
CO2 (7,6%)
NOx (99ppm)
NOx (81ppm)
Electrical supply
230 V ~ 50Hz
Electrical rating
105 W
(F24E)
135 W
(F30E)
f
used at
3A
Level of protection
IPX4D
Fuse rating
1,25mA
Electrical
F24E PLUS - F30E PLUS
Ø Burner injector
1,2 mm
1,2 mm
Inlet pressure
20 mbar
20 mbar
Maxi. Burner pressure
12,5 mbar
13,3 mbar
Mini. Burner pressure
2,35 mbar
2,15 mbar
Gas rate maximum
2,74 m
3
/h
3,45 m
3
/h
Natural Gas (G20) F24E PLUS F30E PLUS
Ø Burner injector
0,73 mm
0,73 mm
Inlet pressure
29 mbar
29 mbar
Maxi. Burner pressure
23,2 mbar
25,5 mbar
Mini. Burner pressure
4,5 mbar
3,73 mbar
Gas rate maximum
2,03 kg/h
2,57 kg/h
Butane Gas (G30) F24E PLUS F30E PLUS
Ø Burner injector
0,73 mm
0,73 mm
Inlet pressure
37 mbar
37 mbar
Maxi. Burner pressure
29,8 mbar
32,5 mbar
Mini. Burner pressure
5,7 mbar
4,7 mbar
Gas rate maximum
2,01 kg/h
2,53 kg/h
Propane Gas (G31) F24E PLUS F30E PLUS
Hot water
F24E PLUS F30E PLUS
Heat input (max) NET Q
25,9 kW
32,6 kW
88,370 BTU/H 111,231 BTU/H
Heat input (min) NET Q
12,3 kW
12,5 kW
41,967 BTU/H
42,650 BTU/H
Heat output (max) GROSS P
23,6 kW
29,6 kW
80,523 BTU/H
100,995 BTU/H
Heat output (min) GROSS P
10,6 kW
10,3 kW
31,731 BTU/H
35,144 BTU/H
Maximum hot water temperature
65
°
C
65
°
C
Minimum hot water temperature
38
°
C
38
°
C
Specific flow rate (for 30
°
C temp rise)
11,3 l/min.
14,1 l/min.
Threshold flow rate
1,7 l/min.
1,7 l/min.
Maximum supply pressure
10 bar
10 bar
Minimum supply pressure
0,5 bar
0,5 bar
BLUE Safety valve,
10 bar
10 bar
The
Themaclassic F24E Plus and
Themaclassic F30E Plus
is delivered in two separate packages:
• The boiler hanging bracket and isolating
valves.
• The flue system
11564a
Diagram 1.1
Net lift weight (boiler only)
39 kg (F24E) 41 kg (F30E)
Gross lift weight (boiler and packaging)
41 kg (F24E) 43 kg (F30E)
365
232
798
450