10
TECHNICAL DATA
THELIA 23 THELIA 23 E
THELIA SB 23
Heating useful output,
adjustable from... (kW)
8,9
8,9
8,9
(BTU/H)
30,000 30,000 30,000
to... (kW)
23,3
23,3
23,3
(BTU/H)
80,000 80,000 80,000
Efficiency
(%)
82,3
82,3
82,3
Heating max. output temperature
(
°
C)
87
87
87
Heating regulation
adjustable by user between 30 and 87
°
C
Heating system expansion vessel, effective capacity
(l)
6,5
6,5
6,5
System max. capacity at 75
°
C
(l)
140
140
140
Safety valve, maximum service pressure
(bar)
3
3
3
Products outlet
(Ø)
60
60
60
Fresh air inlet
(Ø)
100
100
100
Output in hot water mode,
automatically variable from... (kW)
8,9
8,9
—
(BTU/H)
30,000 30,000
—
to... (kW)
23,3
23,3
—
(BTU/H)
80,000 80,000
—
Max. hot water temperature
(
°
C)
65
65
—
Operating threshold flow rate in sanitary hot water mode
(l/min.)
3
3
—
Specific flow rate (for 30
°
C temperature rise)
(l/min.)
11
11
—
Mini. supply pressure
(bar)
0,3
0,3
—
Max. supply pressure
(bar)
10
10
—
Electrical supply
(V)
230
230
230
Amperage
(A)
0,73
0,73
0,73
Max. power absorbed
(W)
130
130
130
Ø Pilot injector
(mm)
0,28
—
0,28
Ø Burner injector
(mm)
1,20
1,20
1,20
Inlet pressure
(mbar)
20
20
20
Gas rate (maximum)
(m
3
/h)
2,70
2,70
2,70
Gas rate (minimum)
(m
3
/h)
1,13
1,13
1,13
Ø Pilot injector
(mm)
0,18
—
0,18
Ø Burner injector
(mm)
0,73
0,73
0,73
Inlet pressure
(mbar)
29
29
29
Gas rate (maximum)
(kg/h)
2,01
2,01
2,01
Gas rate (minimum)
(kg/h)
0,84
0,84
0,84
Ø Pilot injector
(mm)
0,18
—
0,18
Ø Burner injector
(mm)
0,73
0,73
0,73
Inlet pressure
(mbar)
37
37
37
Gas rate (maximum)
(kg/h)
1,98
1,98
1,98
Gas rate (minimum)
(kg/h)
0,83
0,83
0,83
Ø Pilot injector
(mm)
—
—
—
Ø Burner injector
(mm)
—
2,40
—
Inlet pressure
(mbar)
—
8
—
Gas rate (maximum)
(m
3
/h)
—
3,88
—
Gas rate (minimum)
(m
3
/h)
—
1,63
—
Natural Gas
(G20)
Butane
(G 30)
Pr
opane
(G31)
Town gas
(G130)
Содержание THELIA 23
Страница 1: ...1 THELIA THIS IS A CAT II2H3 APPLIANCE 01773 828100 IN WARRANTY TECHNICAL HELPLINE 01773 828400...
Страница 30: ...30...
Страница 31: ...31...