background image

14

SERVICING / MAINTENANCE - OPALIS 5

lift pilot until pilot tube (

1

) slips out of brass tube

(

9

), then pull forward away from heater until scoop

support stirrup is free

brush interior of scoop with soft brush

clean upper pilot injector (

4

) by immersing ex-

tremity of scoop in 15 % acetic acid solution

clean lower part of tube by blowing through

unscrew brass tube (

9

) and blow through up-

per part

clean lower pilot injector (

3

) by brushing lightly

and blowing through

refit parts in reverse order to removal.

Cleaning of blockage safety device

The tube and its cradle having been taken out
(see dismantling procedure in "

Cleaning of pilot

"

paragraph), check that there is no obstruction in
Ø 8 hole in element pipe.

NB : 

the making safe of the appliance by the

blockage safety device involves cleaning or re-
placing the element.

Diagram 11

6

5

4

1

3

2

9

7

8

Heat exchanger descaling

If the heater is installed in a hard water area and
a drop in water flow rate is noticed and/or noise
occurs, the heat exchanger may need descaling.

Proceed as follows :

shut off water supply

remove heat exchanger and fill with a 15 % in-

hibited acid solution

leave to act for 10 to 15 minutes then rinse thor-

oughly

If necessary, repeat operation.

Cleaning of pilot

An obstruction, even partial, of the pilot is identifi-
able by a change in the appearance of the small
flame visible at the top of the pilot tube.
During normal functioning, this flame has the ap-
pearance of a very steady, small blue cone ; when
the pilot is fouled, this flame becomes feebler or
takes on a yellow colour.
 To clean the pilot (

1

) :

turn off appliance

pull back selector control lever (

2

) and unscrew

plastic nut

unscrew, but do not remove, screw (

5

) securing

blockage safety tube (

6

)

separate tube (

6

) from heat exchanger and

remove from cradle, rotating from the back to the
front

remove screw (

5

) and thermocouple nut. Re-

move thermocouple

remove pilot earth screw (

8

)

To ensure the continued efficient and safe
operation of the water heater, it is recommended
that it is checked and serviced annually.

1 -

Pilot tube

2 -

Temperature selector

3 -

Pilot injector

4 -

Upper pilot injector

5 -

Fastening tube/burner support screw

6 -

Blockage safety tube

7 -

Thermocouple solenoid

8 -

Pilot earth screw

9 -

Brass tube mechanism/pilot connection

Des 060

Содержание OPALIS 5

Страница 1: ...1 WATER HEATERS THESE ARE CAT II2H3 APPLIANCE 01773 828100 I N W A R R A N T Y T E C H N I C A L H E L P L I N E 01773 828400...

Страница 2: ...SER SECTION Introduction Page 3 Commissioning Lighting OPALIS 6 9 Commissioning Lighting OPALIS 5 10 Adjustments 11 Draining 15 Mandatory warning notice for CEE countries WARNING this appliance was de...

Страница 3: ...he following versions normal pressure without taps normal pressure with taps These instructions describe how to install and use Saunier Duval appliances It is important to pay attention to the warning...

Страница 4: ...Gas Usable gases TYPE pressure category OPALIS 5 fixed normal II2H3 G20 AAS This appliance is of the II2H3 Gas Category for use with Natural gas G 20 only This appliance is of the II2H3 Gas Category...

Страница 5: ...aximum water pressure 1 pw bar 150 lb in2 Nominal rated heat input Q kW 39895 Btu h Temperature rise C Fresh air flow rate m3 h Natural G20 Appliance inlet pressure mbar Base pilot injector mm Vent pi...

Страница 6: ...t 2 user control 3 flame supervision device 4 temperature selector Shy 094a Diagram 2 2 OPALIS 5 A2 deflector A3 heat exchanger A4 burner B gas mechanism C water mechanism E1 thermocouple E3 atmospher...

Страница 7: ...is the law that all gas appliances are installed by com petent persons in accordance with the above regulations Failure to install appliances correctly could lead to prosecution It is in your own inte...

Страница 8: ...heater to the wall fixing plate and measure the distance between the wall and the back of the heater This will indicate the lenght of hook required Remove the heater Drill a 6 5 mm hole in the wall an...

Страница 9: ...line up with the mark b on the casing see diagram 6 1 Fully depress and then release centre button c the button will remain semi depressed see diagram 6 2 Press piezo igniter button D see diagram 5 I...

Страница 10: ...t up or after long stoppage Turncontrollever 2 diagram 7 toalignredflame a with mark b on front panel diagram 8 1 OPALIS 5 5 3 2 4 6 D 1 Des 060 Description 1 Pilot tube 2 Control knob 3 Temperature s...

Страница 11: ...agram 4 refer to TECHNICAL DATA for the correct inlet pressure Slow ignition The servo gas device ensures automatic adjustment of slow ignition Hot water temperature adjustment These appliances are fi...

Страница 12: ...consistsofatubefixedontotheleftside of the combustion chamber The other end rests on a cradle integral with the stirrup fixed on the burner bracket If the heat exchanger becomes blocked the path offer...

Страница 13: ...ard water area and a drop in water flow rate is noticed and or noise occurs the heat exchanger may need descaling Proceed as follows shut off water supply remove heat exchanger and fill with a 15 inhi...

Страница 14: ...follows shut off water supply remove heat exchanger and fill with a 15 in hibited acid solution leave to act for 10 to 15 minutes then rinse thor oughly If necessary repeat operation Cleaning of pilot...

Страница 15: ...modify the latter without prior notice The technical information contained in our documents are given for guidance only and are without liability DRAINING If there is a risk of frost it is essential t...

Страница 16: ...16 104560 B 07 96...