Copper tubing or plastic hep20 may be used for the
domestic hot water system. Unnecessary pressure losses
should be avoided.
●
A flow restrictor limiting the flow through the boiler
to a maximum of 12 l/min is fitted to the boiler.
●
The boiler will operate with a minimum supply
DOMESTIC HOT WATER SYSTEM DESIGN
pressure of 0,7 bar, but under reduced flow rate. Best
operating comfort will be obtained from a supply pres-
sure of 1 bar.
'Hard Water Areas'
In areas where the water is 'hard', more than 200mg/
litre, it is recommended that a proprietary scale reducer
is fitted in the cold water supply to the boiler.
Shy 120
Diagram 6
BOILER SCHEMATIC
1
-
Domestic thermistor
2
-
Three way valve
3
-
Gas valve
4
-
Gas valve ignition module
5
-
Heating element
6
-
Micro accumulation vessel
7
-
Burner
8
-
Ignition electrode
9
-
Combustion chamber
1 0 -
Micro accumulation vessel thermistor
1 1 -
Main heat exchanger
1 2 -
Air pressure switch
1 3 -
Heating safety valve (3 bar)
1 4 -
Electronic control (PCB)
1 5 -
Domestic water flow sensor
1 6 -
Bypass
1 7 -
Domestic heat exchanger
1 8 -
Pump
1 9 -
Expansion vessel
2 0 -
Heating thermistor
2 1 -
Overheat safety thermostat
2 2 -
Flame sense electrode
2 3 -
Fan
2 4 -
Domestic safety valve
2 5 -
Loss of water sensor
A -
Heating return
B -
Cold water inlet
C -
Heating flow
D -
Domestic hot water outlet
E -
G a s
A
B
C
D F
23
2
3
5
4
6
7
8
9
10
1
13
14
18
17
15
16
19
20
22
24
11
12
25
21