4.2 PIPE CONNECTION
4.1. OUTDOOR UNIT
-
Install de outdoor unit in a place where it will be
free from being dirty or getting by rain as much
as possible.
- During heating operation, drain water flows from
the outdoor unit. Therefore, install the outdoor
unit in a place where the drain water flow will not
be obstructed. (Heat pump model only).
- Do not place animals and plants in the path of
the warm air.
- Take the air conditioner weight into account and
select a place where noise and vibration are
less.
- Select a place so that the warm air and noise
from the air conditioner do not disturb neigh-
bours.
- Provide the space so that the air flow is not bloc-
ked. Also for efficient operation, leave open three
or the four directions front, rear and both sides.
Type A height:
Outdoor Unit above Indoor Unit.
Type B height:
Outdoor Unit below Indoor Unit.
(1) Auxiliary siphons every 7 m.
NOTE:
In vertical layouts always place an oil trap (small siphon)
at the beginning of the vertical stretch. In the case of the
heat pump and with the outdoor unit below the indoor
unit place siphons every 7 m.
4.2.1 INSTALLATION DETAILS
4- OUTDOOR UNIT INSTALLATION
PIPE DETAILS
- When the outdoor unit will be exposed to strong
wind, fasten it with bolts at the places indicated
by the arrows.
- When installing the drain pipe, plug another hole
() in the bottom of the outdoor unit with drain
cap so there is no water leakage.