9
STEAMCORE
Rinse and Flush Operation:
(Silver and Gold Models Only)
All units have the pre-programmed rinse and flush feature. This will
automatically take place after each steam bath, it will happen
approximately 10 minutes immediately after the steam generator has
finished being used and the set time has expired. On the units with the
manual drain (Bronze Package), the Rinse and Flush operation will not
occur. Manually open the drain valve immediately after the steamer stops,
and then close the valve when ready for the next steam bath.
Filtration:
Your steam bath generator has been equipped with an inline filter from the
factory. You may want to add your own secondary external filter or water
softener, although it is not mandatory. This helps reduce foreign particles
that may pass through the water line and lodge in the solenoid valve.
Calcium and other mineral deposits is the number one reason for steamer
breakdown. A secondary filtration system will add additional help to reduce
or remove these components from the water prior to it entering the unit
which will help extend the life and minimize maintenance schedules of the
steam bath generator.
Maintenance:
Saunacore steambath generators are designed for unattended operation
and require little maintenance. Other than periodic draining, maintenance
procedures are not required. Every 2 months, or more often in "hard" water
areas, the drain valve should be opened fully flushing out accumulated
materials, salts, and other particles that are natural by-products of boiling
water. Note: For best results, this should be done immediately after using the
steambath generator, while contents are still hot and with the control off.
Semi-annual maintenance is strongy recommended for
commercial units.
Contact Saunacore for details.
General Installation Instructions
(All Steam Bath Units)
IMPORTANT:
Residential build-up from poor water quality may cause an incorrect
reading of the water level control circuit. If this happens, your steam
generator will attempt to clean and flush the system, if that does not
work, it will shut down completely and the led display on the keypad will
flash continuously. This is an indication that your water level control
circuit needs service.
The main cicuit breaker should be switched off immediately and kept off
untill the problem has been corrected.