Control Installation
CAUTION: Do Not route the SSI or SSII
Control cable inside conduit together with
power lines or close to hot water or steam
piping. Doing so may result in a
malfunctioning control.
L3 G
G
NOTE:
SS I Control ma y be located inside or outside of the steam room. The SSII control must be installed in the steam shower.
Main power supply in conduit or use bx (L1, L2, L3, and Ground.)
1. Locating the Control Inside or Outside the Steambath enclosure:
The SSI Control is designed to be installed inside or outside the
steambath enclosure according to personal preference.
It is recommended that the SSI Control is located about 4 to 5 feet
above the floor. The control should be located away from direct shower
spray and must be kept away from hot piping and steam piping. SSI or SSII
control may be siliconed to wall finish.
2. Determine if the installation of an electrical box is required.
The SSI and the SSII Control operates on low voltage signal.
Check your local building codes to determine if the use of an electrical box
is required.
3. The SSI or SSII Control cannot be used together with any other
controls.
SS I Control
Temperature Sensor
(Locate in Steam Shower)
SSII control has the steam shower temperature sensor built into the control keypad.