background image

8

ACCESSORIES

Part No.

Description

Image

KILOG-LITE

Free basic software

 for configuration, and data download (tabular & graphical).

Available for download at 

www.sauermann.us/data-logger

KILOG-3-N

Premium software

 for configuration, data download, and fast and easy data

saving, processing, and calculations.

Available for download at 

www.sauermann.us/data-logger

KBL-AA

1 AA lithium 3.6 V battery

(2 batteries are required for class 320 data loggers)

KAV-320

Safety lock wall mount with padlock

KRB-320

Wired extension

 for KT 320 data loggers probes

In polyurethane, 16' (5 m) length with male and female mini-DIN connectors

(up to 5 extensions can be wired together for greater length requirements)

CK-50

USB / micro-USB cable

 (connects the data logger to a PC)

Recommended accessories to be used with the data loggers

9

TROUBLESHOOTING

Problem

Probable cause and possible solution

No value is displayed, only the icons are present.

The display is set “OFF”. Set it on “ON” with the KILOG software 
(see page 15).

The display is completely off* and there is no 
communication with the computer.

The battery has to be replaced (see page 19).

The display indicates 

“- - - -”

 instead of the measured 

value.

The probe is disconnected. Plug it again to the data logger.

There is no Bluetooth

®

 communication with the data 

logger.

The Bluetooth

®

 is deactivated. Activate Bluetooth

®

 with the 

KILOG software (see page 15).

TROUBLESHOOTING

21

* Only with the KT 320 and KTT 320 data loggers.

Содержание Class 320

Страница 1: ......

Страница 2: ......

Страница 3: ...12 3 9 Connect a probe to the thermocouple input 12 3 10 Dimensions 13 3 10 1 Devices 13 3 10 2 Wall mount option 13 3 11 Warranty period 13 4 USE OF THE DEVICE 14 4 1 Display 14 4 2 Function of LEDs...

Страница 4: ...ise the protection ensured by the device 1 2 Symbols For your safety and in order to avoid damage to the device please follow the procedures described in this user manual and carefully read the notes...

Страница 5: ...mperature humidity light current voltage pulse relative pressure They ensure traceability in the food industry environment as well as validate that industrial installations are functioning properly 2...

Страница 6: ...the computer is carried out via a USB cable with a female micro USB connector 2 8 Mounting The class 320 data loggers are equipped with a magnetic case for easy mounting 6 DEVICE COMPONENTS Selection...

Страница 7: ...from 32 to 2372 F 0 4 C from 0 to 1300 C 0 3 of the reading 0 8 F below 32 F 0 3 of the reading 0 4 C below 0 C S 1 1 F 0 6 C Alarm set points 2 alarm set points per channel 2 alarm set points per ch...

Страница 8: ...122 F 0 4 C from 0 to 50 C 1 5 F below 32 F or above 122 F 0 8 C below 0 C or above 50 C Humidity2 2 RH from 5 to 95 59 to 77 F 15 to 25 C Atm pressure 3 hPa Alarm set points 2 alarm set points per c...

Страница 9: ...s 1 s to 24 h 1 s to 24 h Battery life 7 years2 7 years2 Warranty 1 year 1 year Directives 2011 65EU RoHS II 2012 19 EU WEEE FCC part 153 UL 61010 1 All accuracies specified in this document were cond...

Страница 10: ...ressly approved by Sauermann could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 1...

Страница 11: ...ng 0 5 F from 32 to 248 F 0 4 of the reading 0 3 C from 40 to 120 C 0 24 x 1 97 6 x 50 mm KIRGA 150 Immersion probe IP 65 40 to 248 F 40 to 120 C 0 6 F from 40 to 32 F 0 3 of reading 0 5 F from 32 to...

Страница 12: ...and coiled cable Tc K 40 to 482 F 40 to 250 C 2 7 F 1 5 C 30 s 5 9 150 mm 0 12 3 mm Immersion SIT 300 BT Very low temperature immersion probe Deformable lined contact tip with handle and coiled cable...

Страница 13: ...ion 3 11 Warranty period Sauermann data loggers have a 1 year warranty for any manufacturing defect warranty returns must be processed through Sauermann s After Sale Service Department TECHNICAL FEATU...

Страница 14: ...ng slowly 15 seconds at least one threshold has been exceeded during the dataset Operating LED If the green ON LED has been activated it flashes every 10 seconds during the recording period DATASET is...

Страница 15: ...ce state Type of start stop selected Button used Action generated Illustration Waiting for start flashes Start by button Stop Not relevant in this mode Start of dataset Inactive Start by PC date time...

Страница 16: ...Action generated Illustration Group scrolling groups 1 2 and 3 Dataset finished There is no restart after the data set has ended Inactive Measurements scroll Please see the summary table of the groups...

Страница 17: ...probe 1 Min value in Parameter 1 of probe 1 High alarm threshold in Parameter 1 of probe 1 Low alarm threshold in Parameter 1 of probe 1 Parameter 2 of probe 1 Max value in Parameter 2 of probe 1 Min...

Страница 18: ...r reader and follow the installation procedure of the KILOG software More details about the installation procedure in the Kilog user manual 1 Plug the male USB connector of the cable to the computer U...

Страница 19: ...ry hatch and secure the 4 screws with a screwdriver Only use trademark or high quality batteries in order to guarantee proper battery life After the battery replacement the device must be reconfigured...

Страница 20: ...standard gas on the gas connection on the back of the KCC 320 device with the supplied Tygon tube see picture Generate a gas flow of 30 l h Wait for the measurement stabilization about 2 minutes Check...

Страница 21: ...p to 5 extensions can be wired together for greater length requirements CK 50 USB micro USB cable connects the data logger to a PC Recommended accessories to be used with the data loggers 9 TROUBLESHO...

Страница 22: ......

Страница 23: ......

Страница 24: ...amages can happen so please apply the precautionary measures indicated NT_US Class 320 Data Loggers 16 10 18 Non contractual document We reserve the right to modify the characteristics of our products...

Отзывы: