Gas Range Manual
Page 9
Revision: 21 Oct 2011
Gas Pressure.
The authorized person installing this equipment must ensure that the gas
operating pressure is the same as shown on the rating plate and that there is
sufficient gas volume.
The unit and its individual shut off valve must be disconnected from the gas
supply piping system during any pressure testing of the gas supply piping
system at test pressures in excess of 1/2 PSIG (3.45 kPa)
Commissioning.
The authorized person installing this equipment must commission the
equipment - gas leakage, operational checking, adjustments and instructing
the owner on use of the equipment are prescribed requirements.
The equipment must be isolated from the gas supply piping system by closing
its individual manual shut off valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 PSIG (3.45
kPa)