Gas Range Manual
Page 21
Revision: 21 Oct 2011
OPEN AND GRILL BURNER ADJUSTMENTS
Leak Test
Ensure that all valves are in the OFF position.
Turn on the main gas supply valve.
Light all pilots.
Leak test all valves and fittings using approved methods.
Correct any leaks as required and re-check.
Shut off all valves and set thermostat dials to “OFF” position.
Test Point Pressure
The open top and grill gas pressure test point is located on the gas manifold.
The gas manifold and pressure test point is accessed by removing the gas
valve control knobs and the front panel. The test point pressure is shown in the
Nominal Gas Consumption Table and is set with two open top burners
operating at maximum setting.
Burner Adjustment
The open top, grill and oven burner orifices are fixed as specified and cannot
be adjusted. The specified gas rate will be achieved if the gas supply
pressure and test point pressure is correct.
A distinct blue flame over the entire port area of the burner will be achieved at
full rate when the air supply is correct and the air shutter is properly adjusted.
If the flame is yellow and wavy, the cause needs to be established.