![Saturn South SS9005 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/saturn-south/ss9005/ss9005_user-manual_1202122010.webp)
10
Figure 2: Mini Three Phase Meter monitoring three individual single phase loads
5.
If your Mini Three Phase Meter has switching capability, the two terminals marked 'SWITCH'
are connected internally to an isolated relay rated for 5A at 240V. The front panel button will
glow red to indicate that the relay is closed. This relay can be used to switch an external
relay, contactor, or control system. Refer to the relevant documentation when connecting
this Mini Three Phase Meter to a third party control device. See Section
6 Switching
for
more information.
6.
Apply power to the device. The button will blink continuously between green and red to
indicate that the device is in factory reset state. If the device is not in its factory reset state
when it is initially powered up, it can be reset by pressing and holding the front panel button
for at least 10 seconds, until the button starts to blink continuously between green and red.