SATO 8264-00 Скачать руководство пользователя страница 7

 

 

 

 

2.    Loading the Battery 

 

When using the unit for the first time or when the low battery mark lights up, 

replace the 

battery with a new one as described below.

 

 

(1)  Open the battery lid. 

 
 
 

 

(2)  Check  both  polarities  (+/-)  of  the  battery  snap 

fasteners and a 9V battery 6F22 (006P).   
Insert the battery in place. 
 
 

(3)  Close the battery lid so that it clicks. 
 
 

Cautions 

 

  Replace the battery immediately when the low-battery mark on the LCD lights.   

  Measurements  while  the  low-battery  mark  is  lit  may  affect  the  accuracy,  possibly  resulting  in 

malfunction of the thermometer. 

  Do not dispose of the used battery in a fire. 

  The battery is a factory set.    The battery was used for monitoring and its battery life may be 

shortened   

 

 
 

3.    Putting Vinyl Cover on Thermometer 

 
It is recommended to use the thermometer putting the vinyl cover on top and grip of the unit. The 
cover  will  help  absorb  shock  in  case  the  unit  is  dropped  accidentally,  and  protect  the  unit  from 
becoming dirty during use. The thermometer is shipped being put the cover on.   
 
1)  Hold the opening of the cover wide when inserting the unit. 

 

2)  Fix the snap fastener (button) on the cover to secure the unit.   
 

NB.    * When removing the cover, take off the lens cap first from the hand strap. Be careful not to 

lose it. 

NB.   

When using the cover, static electricity may be charged inside the cover, and the indicated 
value may become unstable. In that case, remove the cover and use.

 

Содержание 8264-00

Страница 1: ...Instruction Manual for No 8264 00 Infrared Thermometer Model SK 8920 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english M12...

Страница 2: ......

Страница 3: ...et the unit touch the object to be measured If the unit touches a hot object it may result in measurement errors or failure Never disassemble or modify this unit Doing so may result in failure Do not...

Страница 4: ...rung gauze or the like that has been dipped in warm water with neutral detergent Do not wipe the temperature measurement section infrared lens directly with gauze For details refer to Maintenance Glas...

Страница 5: ...rement spot With the laser marker set on a laser sighting is output so that you can instantly identify the spot being measured Auto power off function The power will be turned off automatically if the...

Страница 6: ...entally 4 Measurement trigger Pull the trigger to turn on and activate temperature measurement 5 LCD Displays the temperature reading and other related information 6 Laser marker key Sets the laser ma...

Страница 7: ...battery is a factory set The battery was used for monitoring and its battery life may be shortened 3 Putting Vinyl Cover on Thermometer It is recommended to use the thermometer putting the vinyl cove...

Страница 8: ...The measurement spot size of this thermometer changes in accordance with the distance as shown below The diameter of the measuring spot shown above is defined on the basis of the area that receives 90...

Страница 9: ...ture range state 4 3 Low Temperature Measurement The operation ambient is 0 to 50 C The measurement in the lower than 0 C state such as in a refrigerator cannot be done If the ambient temperature fluc...

Страница 10: ...iming at the point illustrated above Refer to the figure as a guide Do not look into the laser marker or point it at anybody s eyes Doing so may damage your eyes Keep the unit out of reach of children...

Страница 11: ...95 Resolution 1 C at higher than 100 C 0 1 C at other than above Emissivity Selectable among 0 98 0 92 and 0 85 Distance to Spot size D S 10 1 Detector Thermopile Spectral response 8 to 14 m Response...

Страница 12: ......

Отзывы: