SATO 8264-00 Скачать руководство пользователя страница 5

 

 

 

 

Features 

 

  Measures surface temperature instantly: 

The advantage of the non-contact infrared method is quick-response measurement, and the 
single-hand-held unit allows easy operation by using trigger type measurement button. 

 

  Non-contact, clean measurement: 

Ideal for food processing industries where clean and hygienic measurement is required. 
 

  Selectable emissivity 

Emissivity is selectable by button among 0.98, 0.92 and 0.85. 
 

  Easily visible measurement spot 

With the laser marker set on, a laser sighting is output so that you can instantly identify the 
spot being measured. 
 

  Auto power-off function:   

The  power  will  be  turned  off  automatically  if  the  unit  is  not  operated  for  approximately  six 
seconds, thus conserving battery power if you forget to turn the power off. 
 

  Auto Hold function: 

A measured value of temperature is automatically held (fixed) for approximately six seconds. 
 

  Putting the cover on top and grip of the unit will protect the unit from becoming dirty during use 

and absorb shock in case the unit is dropped accidentally.   
 

  Top and grip covers 

Protects the unit from dirt or dust.   

 

 

Содержание 8264-00

Страница 1: ...Instruction Manual for No 8264 00 Infrared Thermometer Model SK 8920 3 4 Kanda kajicho Chiyoda ku Tokyo 101 0045 Japan URL http www sksato co jp english M12...

Страница 2: ......

Страница 3: ...et the unit touch the object to be measured If the unit touches a hot object it may result in measurement errors or failure Never disassemble or modify this unit Doing so may result in failure Do not...

Страница 4: ...rung gauze or the like that has been dipped in warm water with neutral detergent Do not wipe the temperature measurement section infrared lens directly with gauze For details refer to Maintenance Glas...

Страница 5: ...rement spot With the laser marker set on a laser sighting is output so that you can instantly identify the spot being measured Auto power off function The power will be turned off automatically if the...

Страница 6: ...entally 4 Measurement trigger Pull the trigger to turn on and activate temperature measurement 5 LCD Displays the temperature reading and other related information 6 Laser marker key Sets the laser ma...

Страница 7: ...battery is a factory set The battery was used for monitoring and its battery life may be shortened 3 Putting Vinyl Cover on Thermometer It is recommended to use the thermometer putting the vinyl cove...

Страница 8: ...The measurement spot size of this thermometer changes in accordance with the distance as shown below The diameter of the measuring spot shown above is defined on the basis of the area that receives 90...

Страница 9: ...ture range state 4 3 Low Temperature Measurement The operation ambient is 0 to 50 C The measurement in the lower than 0 C state such as in a refrigerator cannot be done If the ambient temperature fluc...

Страница 10: ...iming at the point illustrated above Refer to the figure as a guide Do not look into the laser marker or point it at anybody s eyes Doing so may damage your eyes Keep the unit out of reach of children...

Страница 11: ...95 Resolution 1 C at higher than 100 C 0 1 C at other than above Emissivity Selectable among 0 98 0 92 and 0 85 Distance to Spot size D S 10 1 Detector Thermopile Spectral response 8 to 14 m Response...

Страница 12: ......