SATEL
XD-2
9
6. Detector test
Make sure the LED is enabled, before you test the detector.
Check if the LED turns ON:
magnetic contact: after moving the magnet away from the detector (opening the window
or door),
shock detector: after impact against the surface protected by the detector,
The shock detector range depends on the type of surface on which the detector is
installed. The specified detection range (up to 3 m) should be considered an
approximate value. The actual detection range should be tested.
water flood detector: after submerging the flood probe contacts in water.
If a detector is connected to the SNS input, check if the LED on the XD-2 detector will turn
ON when that detector is violated.
7. Specifications
Supply voltage .................................................................................................... 12 VDC
±
25%
Standby current consumption ....................................................................................... 12.5 mA
Maximum current consumption ........................................................................................ 14 mA
Outputs
NC alarm (NC relay, resistive load) ............................................................. 40 mA / 24 VDC
S alarm (NC relay, resistive load) ................................................................ 40 mA / 24 VDC
tamper (NC) ................................................................................................. 40 mA / 24 VDC
Relay contact resistance
NC alarm output ............................................................................................................
26 Ω