SATEL VIVER
5
(which are not locked, i.e. their INE, INF, ING, INH inputs are not shorted to common
ground).
Figure 4. Video signal live view window.
The window provides the option of changing the video signal source (A, B, C or D
camera). The
button invokes the live view image from the chosen camera. The
button stops the transfer at the last frame. The fit size option fits the size of
displayed video signal to the image window size. The green frame appearing inside the
view window indicates that a new image is coming from the given camera.
7 – Button enabling selection of the computer COM port through which communication with
the module is to be effected.
8 – Button making it possible to exit the program.
9 – Current date and time of the module internal clock data.
10 – Cameras. Tick off appropriate boxes in this field to indicate from which cameras (A, B,
C, D) the image is to be recorded. Also, fix the number of images which are to be
recorded before and after the event (in the 1 to 255 range in both cases). The minimum
sequence length is 3 images (1 captured before, 1 at the triggering moment and 1 after).
11 – Information on the status of cameras and inputs. With regard to the cameras, colors
have the following meaning:
– green: the module is to record camera image, signal from the camera OK,
– red: the module is to record camera image, but there is no signal from the camera,