16
VERSA Plus LTE
SATEL
Expander address
Zone numbers
decimally
hexadecimally
12
0C
7-14
13
0D
15-22
14
0E
23-30
Table 2.
5.5.6 Connecting the hardwired output expander
One INT-O / INT-ORS / CA-64 O / CA-64 OPS expander can be connected to the control
panel. This enables expansion of the system by adding 8 programmable wired outputs.
Address 15 (0Fh) must be set in the expander. In the case of the INT-ORS expander, you
must also use the DIP-switches to define how the expander is to be identified (for detailed
information please refer to the manual delivered with the expander).
The INT-O expander is identified as CA-64 O (the dedicated power supply not
connected to the expander) or CA-64 OPS (the dedicated power supply connected to
the expander).
Fig. 12. Connecting the INT-O expander to the control panel.
Fig. 13. Setting address, as in the case of the INT-O expander.
5.5.7 Connecting proximity card arm/disarm devices
Up to 6 INT-CR / INT-IT / INT-IT-2 devices can be installed in the system. Addresses from
the 16 (10h) to 21 (15h) range should be set in the devices.
All the proximity card arm/disarm devices are identified by the control panel as the
INT-IT module.