SATELLINE-M3-TR8 /-TR9 / -R9
Integration Guide, Version 2.2
44
13.
APPENDIX C
13.1
SL COMMANDS – SATELLINE-M3-TR9/R9, Freewave
Receiver parts applies to SATELLINE-M3-R9 receiver module, forced permanently to
Point to
Multipoint Slave (RX Only) mode
(can’t be changed)
.
General format of the Freewave related SL
commands is:
Set Emulation mode settings:
SL~E=M1,I<index>,A<Attribute1>,B<Attribute2>,C
<Attribute3>,...
prefix M indicates the emulation mode (M1
means Freewave, M2 means something else...)
prefix I is the index indicating the specific setting
under the emulation mode
prefixes A, B, C, ... indicate the corresponding
attributes
Get Emulation setting: SL~E?M1,I<index>
Format of response is
M1,I<index>,A<Attribute1>,B<Attribute2>,C<Attri
bute3>,...
Get Emulation settings summary: SL~E?
Response is reserved for the summary of the
emulation settings (to be defined later)
Setting
name
Type
Values
(Range)
Value descriptions SL Command
Modem
Mode
Uint8
0 -7 , A-B 0: Point to Point
Master
1: Point to Point
Slave
2: Point to
MultiPoint Master
3: Point to
MultiPoint Slave
4: Point to Point
Slave/Repeater
5: Point to Point
Repeater
6: Point to Point
Slave/Master
Switchable
7: Point to
Multipoint Repeater
A: Mirrored Bit
Master
B: Mirrored Bit
Slave
SL~E=M1,I1,A<Mode>
<Mode> = [0-7,A-B] as presented on the left