– output is active, when the control panel is running in service
mode.
23
.
A
RM STATUS
(
REPORTED
)
– output is active, when the system is armed and information
about arming has been sent to the monitoring station (if reporting is disabled, the output is
active when the system is armed).
7.2 Output parameters and options
Output name
[48.Names]
– individual name of the output (up to 16 characters).
Cut off time
[42.Duration]
– time during which the output is active. Entering 0 changes the
operation mode of some outputs:
– outputs activated by triggering alarm will remain active until the alarm is cleared,
– 5. DURESS
ALARM
and 14. C
HIME
outputs will remain active until starting the 3.O
UTPUTS
RESET
user function,
– 13. Z
ONE VIOLATION
output will be active when the zone is violated,
– 15. C
ONTROLLED
output will remain active until repeated zone violation, stopping timer or
deactivating from keypad, etc.
Triggering zones
[43.Zones]
– the zones whose status has effect on the output status.
Arming modes
[43.Zones]
– arming modes which affect the output status.
Troubles
[43.Zones]
– troubles during which the output is active.
Assigned to part. 1
[451.P.1 outputs]
– if this option is enabled, the output is controlled by
events related to partition 1 (alarm in partition 1, clearing alarm in partition 1 etc.).
Assigned to part. 2
[452.P.2 outputs]
– if this option is enabled, the output is controlled by
events related to partition 2 (alarm in partition 2, clearing alarm in partition 2 etc.).
Polarity +
[453.Po)]
– the option defines how the outputs will operate (see the table
below). If the option is disabled, the output is inverted. The option does not apply to
wireless outputs.
“–” terminal of high-current output / low-current output
option enabled
(normal polarity)
option disabled
(reverse polarity)
output inactive
disconnected from ground
shorted to ground
output active
shorted to ground
disconnected from ground
Table 4. Mode of output operation depending on the P
OLARITY
+ option.
Pulsed
[454.Pulsed]
– if this option is enabled, the output is pulsating when it is active. The
option does not apply to the 1. E
XTERNAL SIREN
, 2. I
NTERNAL SIREN
, 11. F
IRE DETECTORS
P
OWER SUPPLY
and 20. A
RM
/
ALARM STATUS OUTPUTS
. The option does not apply to wireless
outputs.
Arm/Disarm/clear sign.
[455.Arm/Dis/Clr]
– if this option is enabled, the output will signal:
– starting the arming procedure (if the exit delay time is 0, the system is armed
immediately)
– 1 pulse,
– disarming – 2 pulses,
– clearing alarm – 4 pulses,
– denial of arming or arming procedure failure – 7 pulses.
The signaling is triggered if a keyfob or zone is used to arm / disarm the system or clear
alarm. Pulse duration is about 0.3 second. Option for the 1. E
XTERNAL SIREN
, 2. I
NTERNAL
SIREN
, 3. B
URGLARY
, 4. FIRE
ALARM
, 5. DURESS
ALARM
, 6. PANIC
ALARM
, 7. MEDICAL
ALARM
, 8. A
LARM
-
NOT VERIFIED
, 9. A
LARM
-
VERIFIED
and 10. T
AMPER ALARM
outputs.