OPAL Plus
Outdoor dual technology motion detector
Firmware version 3.00
opal_plus_en 03/21
SATEL sp. z o.o.
• ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Страница 1: ...OPAL Plus Outdoor dual technology motion detector Firmware version 3 00 opal_plus_en 03 21 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...
Страница 2: ...under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being...
Страница 3: ...mounting 8 Angle bracket mounting 8 Ball bracket mounting 9 Connecting the additional tamper switch 11 5 Configuring the detector 11 Starting configuration mode 11 Signaling in the configuration mode...
Страница 4: ...e LED indicators Remote LED enable disable Remote configuration mode enable disable Supervision of motion detection system and supply voltage Tamper protection against cover removal and tearing enclos...
Страница 5: ...tor will signal a trouble The trouble is indicated by the activation of alarm output and the steady light of all LED indicators The trouble signaling will continue as long as the trouble persists LED...
Страница 6: ...sabled If the detector is used in the INTEGRA INTEGRA Plus alarm system you can connect to the terminal the OC type control panel output programmed e g as Zone test status or BI switch Remote configur...
Страница 7: ...g MODE button used for the detector configuration see Configuring the detector PIR sensor dual element pyrosensor tamper switch activated by cover removal fixing screw holes dusk sensor On the other s...
Страница 8: ...n intruder will be across the coverage pattern Fig 3 III Don t install the detector closer than 3 meters from the moving objects e g tree branches bushes laundry etc Fig 3 IV Don t direct the detector...
Страница 9: ...e angle bracket see Angle bracket mounting or to the ball bracket see Ball bracket mounting In Figure 6 possible ways of mounting the detector are shown 5 Fasten the electronics module in the enclosur...
Страница 10: ...ng the tamper switch in one of two available positions The place of tamper switch installing depends on the way of angle bracket mounting If the tamper switch is to be installed in the other position...
Страница 11: ...mper switch Fig 8 II screw the tamper unit to the ball bracket Fig 8 IV 2 Run the cable through the opening in the handle of the bracket 3 Using wall plugs screw anchors and screws fasten the ball bra...
Страница 12: ...10 OPAL Plus SATEL...
Страница 13: ...nds or apply the common ground to the SVCE terminal After starting the configuration mode the green LED starts to blink it means that you can configure the sensitivity of the microwave sensor Signalin...
Страница 14: ...nsitivity detection threshold of the sensor Pressing the button restores default settings for the configured sensor By pressing the next sensor or the previous sensor go to another sensor configuratio...
Страница 15: ...be tested 3 Check that moving in the coverage area will make the violation signaling LED light up 4 If it is needed readjust sensitivity and check the sensor operating 7 Specifications Supply voltage...
Страница 16: ...d installation height 2 4 m Security grade according to EN 50131 2 4 Grade 2 Standards complied with EN50131 1 EN 50131 2 4 EN50130 4 EN50130 5 IP code IP54 Environmental class according to EN50130 5...