background image

SATEL MMD-300 

4.  Select the place of installation. Check that the transmissions from the detector placed at 

that point reach the MICRA alarm module. In order to send a transmission, close and 
open the tamper contact. If the alarm transmission is received, continue with the 
installation. If the alarm transmission is not received, select a different mounting location 
and repeat the test. 

5.  If a detector is to be connected to the additional input terminals, make a hole in the 

enclosure base, run the wires through the hole and fasten them to screw terminals. The 
maximum permissible length of wires: 3 m. 

6.  Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting 

surface. 

7.  Secure the magnet, taking into account the maximum permissible distance from the reed 

switch (see Fig. 4). 

8.  Close and open the tamper contact to activate the test mode, and then close the detector 

enclosure. 

9.  Check whether the LED lights up after moving the magnet away (i.e. opening a window or 

door). If the additional input is used, make sure that violation of the detector connected to 
it will cause the LED to light up. 

 

 

Fig. 2.  The enclosure opening manner. 
Fig. 3.  Enclosure dimensions and location of reed switches. 1 – bottom reed switch. 2 – side 

reed switch. 

 

Отзывы: