4. Select the place of installation. Check that the transmissions from the detector placed at
that point reach the MICRA alarm module. In order to send a transmission, close and
open the tamper contact. If the alarm transmission is received, continue with the
installation. If the alarm transmission is not received, select a different mounting location
and repeat the test.
5. If a detector is to be connected to the additional input terminals, make a hole in the
enclosure base, run the wires through the hole and fasten them to screw terminals. The
maximum permissible length of wires: 3 m.
6. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the mounting
surface.
7. Secure the magnet, taking into account the maximum permissible distance from the reed
switch (see Fig. 4).
8. Close and open the tamper contact to activate the test mode, and then close the detector
enclosure.
9. Check whether the LED lights up after moving the magnet away (i.e. opening a window or
door). If the additional input is used, make sure that violation of the detector connected to
it will cause the LED to light up.
Fig. 2. The enclosure opening manner.
Fig. 3. Enclosure dimensions and location of reed switches. 1 – bottom reed switch. 2 – side
reed switch.