background image

 

 

VERSA-MCU 

MICRA wireless system controller 

versa-mcu_sii_en 06/20 

Quick installation guide 

Full manual is available on 

www.satel.eu

 

The device should be installed by qualified personnel. 

Before installation, please read the full manual thoroughly. 

Changes, modifications or repairs not authorized by the manufacturer shall void 
your rights under the warranty. 

Disconnect power before making any electrical connections. 

The  device  should be installed indoors, in spaces with normal air humidity. When choosing 
the installation location, remember that thick masonry walls, metal partitions etc. reduce the 
radio signal range. Installing the device  in close vicinity of electrical systems is not 
recommended, since it can affect the range of radio signal. 

Run the cables to be used for making connection to the location where the device will be 
installed. Use an unshielded non-twisted cable. The cabling should not be run in close vicinity 
of low-voltage electrical system wires, and especially of power cables for high-power 
equipment (such as electric motors). 

1.  Open the controller enclosure (Fig. 1). 

2.  Place the enclosure base against the wall and mark location of the mounting holes. 

3.  Drill holes for wall plugs (anchors) in the wall. 

4.  Make the cable entry opening at the base. 

5.  Run the wires through the prepared opening. 

6.  Using wall plugs and screws, secure the enclosure base to the wall (Fig. 2). The wall 

plugs delivered with the device are intended for concrete, brick, etc. For other types of 
surface (drywall, styrofoam), use the appropriately selected wall plugs. 

7.  Connect the CLK, DAT and COM terminals to the corresponding terminals of the control 

panel communication bus (Fig. 3). 

8.  Connect the power wires to the +12V and COM terminals. If the distance to the control 

panel is less than 300 meters, the controller can be supplied directly from the control 
panel (Fig. 3). If the distance to the control panel is higher, the controller must be supplied 
from another power source, which is located at a closer distance (a power supply or an 
expander with power supply). 

9.  Close the enclosure. 

10. Power up the controller. 

11. Start the identification function in the control panel (see the control panel installer 

manual). The controller will be identified as two devices: INT-RX (address 7) and 
VERSA-MCU (address 8). 