5.  Connect the wires to the corresponding terminals. 
6.  Using the potentiometer and jumpers, set the detector working parameters. 
7.  Replace the cover. 

5.  Start-up and walk test 

Note:  When testing the detector, the LED should be enabled. 

1.  Power-up the detector. The LED will start blinking, which indicates the detector warm-up. 
2.  When the LED stops blinking, check that moving within the coverage area (Fig. 8 shows the 

maximum coverage area – at the maximum sensitivity) will activate the alarm relay and make 
the LED light up. 

6.  Specifications 

Supply voltage ........................................................................................................... 12 V DC ±15% 
Standby current consumption ................................................................................................ 7.5 mA 
Maximum current consumption ................................................................................................. 9 mA 
EOL resistors .................................................................................................................... 2 x 1.1 k

 

Relay contacts rating (resistive load) ...................................................................... 40 mA / 16 V DC 
Detectable speed .............................................................................................................. 0.3...3 m/s 
Alarm signaling period .................................................................................................................. 2 s 
Warm-up period .......................................................................................................................... 30 s 
Recommended installation height ........................................................................................ 2,1...3 m 
Security grade according to EN50131-2-2 ............................................................................ Grade 2 
Standards complied with .................................................... EN 50131-1, EN 50131-2-2, EN50130-5 
Environmental class according to EN50130-5 ................................................................................. II 
Operating temperature range......................................................................................... -30...+55 °C 
Maximum humidity .................................................................................................................. 93±3% 
Dimensions ........................................................................................................... 57 x 123 x 42 mm 
Weight ....................................................................................................................................... 112 g 
 
 
 

The declaration of conformity may be consulted at www.satel.eu/ce 

 
 
 
 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-

298 Gdańsk • POLAND 

tel. + 48 58 320 94 00 

[email protected] 

www.satel.eu 

 