Страница 1: ...ists Remote LED enable disable The LED can be enabled disabled remotely when the jumper is placed across the LED pins in OFF position The LED terminal is provided to allow remote LED enable disable The LED is enabled when the terminal is connected to the common ground and disabled when the terminal is disconnected from the common ground You can connect to the LED terminal an OC type control panel ...
Страница 2: ...p blinking slowly potentiometer for sensitivity adjustment LED enable disable pins If the LED is to be enabled place the jumper as shown in Fig 4 the remote LED enable disable is not available then dual element pyrosensor Do not touch the pyroelectric sensor so as not to soil it 4 Installation Disconnect power before making any electrical connections The mirror requires no cleaning The sealed stru...
Страница 3: ...SATEL IVORY 3 ...
Страница 4: ... up 6 Specifications Supply voltage 12 V DC 15 Standby current consumption 7 5 mA Maximum current consumption 9 mA EOL resistors 2 x 1 1 kΩ Relay contacts rating resistive load 40 mA 16 V DC Detectable speed 0 3 3 m s Alarm signaling period 2 s Warm up period 30 s Recommended installation height 2 1 3 m Security grade according to EN50131 2 2 Grade 2 Standards complied with EN 50131 1 EN 50131 2 2...