2
IVORY
SATEL
3. Electronics board
fixing pins for terminal block. Description of
terminals:
NC
- alarm output (NC relay).
TMP
- tamper output (NC).
COM
- common ground.
12V
- power input.
LED
- remote LED control.
MEM
- alarm memory control.
configuration pins for detector outputs:
the built-in resistors are to be used – place the
jumpers as shown in Fig. 2 (connect the outputs
as shown in Fig. 10),
the built-in resistors are not to be used – place the
jumpers as shown in Fig. 3 (connect the outputs
as shown in Fig. 9).
red color LED to indicate:
alarm – ON for 2 seconds,
alarm memory – blinking rapidly,
trouble – ON,
warm-up – blinking slowly.
potentiometer for sensitivity adjustment.
LED enable/disable pins. If the LED is to be enabled, place the jumper as shown in Fig. 4
(the remote LED enable/disable is not available then).
dual element pyrosensor.
Do not touch the pyroelectric sensor, so as not to soil it.
4. Installation
Disconnect power before making any electrical connections.
The mirror requires no cleaning. The sealed structure of the optical chamber is
dustproof. Removal of the electronics board or the mirror is not recommended.
1. Remove the front cover (Fig. 5).
2. Make the openings for screws and cable in the enclosure base.
3. Run the cable through the cable opening, and if the detector is to be mounted on a bracket,
also through the bracket (Fig. 6).
4. Fix the enclosure base to the wall or to the bracket (Fig. 7).
Содержание IVORY