No auto-reset after 3 tamp.
[No autorst.3t.] – it is possible to disable the feature limiting the
number of tamper alarms from the expander to three (this feature prevents the same
events from being repeatedly recorded and applies to consecutive, non-cleared alarms).
Unlock door if fire
[Doors on fire] – define whether the fire alarm is to have an effect on the
relay status:
no
– the fire alarm has no effect on the relay status – the door will remain locked;
part. fire alarm
– fire alarm in the partition to which the expander belongs will activate the
relay – the door will unlock;
object
fire alarm
– fire alarm in the object to which the expander belongs will activate the
relay – the door will unlock;
fire alarm
– fire alarm in the system will activate the relay – the door will unlock.
4. Using the readers
Description of adding proximity cards and DALLAS chips to the users can be found in the
control panel user manual.
Functions that can be realized by the reader depend on the expander settings, alarm system
status and user rights. It also depends on the expander settings whether the function will be
performed after presenting the card to / touching the reader with the chip, or after holding the
card / chip (the WIEGAND 26 interface readers do not support the card holding function).
When read out, the card / chip code is transmitted through the expander to the control panel.
It is the control panel that decides whether and which function is to be performed. After
receiving feedback from the panel, the reader can signal by means of LEDs or sounds
whether the desired function will be executed or not.
By presenting the card to / touching the reader with the chip you can:
−
activate the relay (unlock the door);
−
disarm the partition to which the expander belongs
−
clear alarm in the partition to which the expander belongs;
−
activate the output type 24. MONO
SWITCH
;
−
control the output type 25. BI
SWITCH
;
−
confirm the guard round;
−
temporarily block the partition to which the expander belongs, if the given partition is
armed.
By holding the card / chip at the reader you can:
−
activate the relay (unlock the door);
−
arm the partition to which the expander belongs;
−
disarm the partition to which the expander belongs
−
clear alarm in the partition to which the expander belongs;
−
confirm the guard round;
−
temporarily block the partition to which the expander belongs, if the given partition is
armed.