Satel INT-R Скачать руководство пользователя страница 10

10 INT-R 

SATEL 

1 long beep every 3 seconds, followed by a series of short beeps for 10 seconds 

and 1 long beep 

– exit delay countdown (if the delay time is shorter than 10 seconds, only 

the final sequence of short beeps will be generated). 

A sequence of 7 beeps of diminishing duration, repeated every few seconds 

– auto-

arming delay countdown. 

1 short beep every 150 ms

 – long open door. 

2 short beeps every second

 – entry delay countdown. 

Continuous beep

 – alarm. 

1 long beep every second

 – fire alarm. 

Note:

 If the device is working as the CA-64 SR expander, which supports the CZ-EMM 

readers manufactured until May 2005, the alarm will be signaled in the same way as 
the fire alarm, i.e. by a long beep every second. 

Beeps generated after reading the card / chip code 

1 short beep

 – confirmation of the card / chip code readout. 

2 short beeps

 

repeated three times 

– the user of the given card / chip should change the 

code. 

3 short beeps

 – depending on the current partition status: 

–  starting the arming procedure (which is equivalent to arming if no exit delay has been 

programmed for the partition), 

–  disarming and/or alarm clearing. 

4 short beeps

 

and 1 long beep 

– confirmation of: 

–  turning on the relay (which can be accompanied by disarming / alarm clearing); 
–  turning off the relay; 
–  activating the 24.

 

MONO

 SWITCH

 type output; 

–  switching over the 25. BI

 SWITCH

 type output; 

– guard round; 
–  temporarily blocking the armed partition. 

1 long beep

 – refusal of arming (the installer can configure the alarm system so that the 

arming is impossible when e.g. a zone is violated in the partition, or a failure has 
occurred). 

2 long beeps

 – unknown card / chip. 

3 long beeps

 – refusal to execute the function. 

5. Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption ........................................................................................110 mA 
Maximum current consumption ......................................................................................150 mA 
Relay contacts rating (resistive load) ................................................................... 5 A / 30 V DC 
Environmental class.................................................................................................................II 
Operating temperature range.............................................................................-10 °C...+55 °C 
Maximum humidity ..........................................................................................................93±3% 
Dimensions ........................................................................................................... 140 x 68 mm 
Weight.................................................................................................................................80 g 
 

Содержание INT-R

Страница 1: ...Determine the expander operating mode see SELECTING THE EXPANDER OPERATING MODE 3 With the DIP switches set the appropriate expander address To set an address use the switches 1 5 The address must be...

Страница 2: ...power source which is located at a closer distance a power supply unit or an expander with power supply 11 Turn on the power 12 Start the identification function in the control panel Depending on the...

Страница 3: ...perating mode The device can operate as I CA 64 SR expander supporting the CZ EMM readers CZ EMM CZ EMM2 CZ EMM3 and CZ EMM4 manufactured from May 2005 factory default setting II CA 64 SR expander sup...

Страница 4: ...r B Terminal description Color of reader wire GA GB 12 V DC power supply red SIG1A SIG1B data 0 green SIG2A SIG2B data 1 black COM COM common ground blue BPA BPB sound control BEEPER yellow LD1A LD1B...

Страница 5: ...d DALLAS chip the relay is active for the RELAY ON TIME Fixed ON time OFF if door open ON open off after reading the code of proximity card DALLAS chip the relay is active until the door is opened the...

Страница 6: ...the 93 UNAUTHORIZED ACCESS type output Alarm on unauth access Unauth alarm this option is available when the AUTHORIZATION CONTROL is enabled If both options are enabled and the partition to which th...

Страница 7: ...e of the BI OUTPUTS type you can control the outputs of 25 BI SWITCH type Control MONO output MONO outs ctr using the card chip assigned to a code of the MONO OUTPUTS type you can activate the 24 MONO...

Страница 8: ...holding the card chip the WIEGAND 26 interface readers do not support the card holding function When read out the card chip code is transmitted through the expander to the control panel It is the con...

Страница 9: ...tarting the arming procedure which is equivalent to arming if no exit delay has been programmed for the partition disarming and or alarm clearing 4 short blinks and 1 long blink confirmation of turnin...

Страница 10: ...card chip should change the code 3 short beeps depending on the current partition status starting the arming procedure which is equivalent to arming if no exit delay has been programmed for the parti...

Страница 11: ...The declaration of conformity may be consulted at www satel eu ce SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Отзывы: