5.4 End-of-line resistance
The resistance data are stored in the keypad. Before you proceed to programming the
resistor values, read out the data from the keypad ("Read" button), and, after the
programming is completed, write them to the keypad ("Write" button). These data are
not read and written after you click the
button in the program main menu.
For the keypads with firmware version 1.02 (or newer), which are working with the
INTEGRA Plus control panels, the values of end-of-line resistors are not programmed
individually for each keypad (the "EOL resistance value" tab is not available). You
must use the same resistors as those for the control panel onboard zones (the value of
EOL resistors for control panel onboard zones is programmable).
The value of EOL resistors is programmable. You can program the value of R1 and R2
resistors for Double EOL configuration (numbering of the resistors is shown in Fig. 10). The
resistor value can range from 500
to 15 k
, however the sum of programmed values must
not exceed 15 k
. For the R2 resistor, you can program value 0. In such a case, the value of
resistors used in the Double EOL configuration must be equal to half the value programmed
for the R1 resistor, but not less than 500
. By default, the following values are programmed:
R1 = 1,1 k
;
R2 = 1,1 k
.
The resistor value for Single EOL configuration is the sum of values programmed as R1 and
R2.