background image

22 

User manual 

GSM LT-2 

Where the number of digits is not precisely defined (e.g. a telephone number), such 
a parameter is described with the following symbol: 

[?...]

The numbers of telephones/PAGER stations may contain special characters: 

#

*

+

. In order 

to program such a character from the telephone keypad, call the programming function and 
press successively the two keys: 
[*][1] = 

#

 

[*][*] = 

[*][0] = 

Entering a correct command is signaled in the handset by three short beeps (SSS), while 
commands which are incomprehensible or have an incorrect number of characters are 
signaled by two long beeps (LL). 
The function completed, the module returns to the programming mode. If you hang up, 
the module will quit the programming mode and return to the normal operating mode. 

12.2.3 Function  list 

[0][1][*][*][?][?][?][?][#]

 – SIM card 

PIN

 

code 

(4 digits). The code saved in module memory 

does not change the code stored on the SIM card. The [0][1][*][*][#] sequence deletes the 

PIN code from module memory. 

[0][2][*][*][?...][#]

 – 

SMS

 

center number 

– the telephone number necessary for sending text 

messages. The number of its digits must be within the range of 1...16. The entered 
number depends on the GSM network, where the telephone is activated. 

It must be 

preceded by the country code

 suitable for the operated network. 

The [0][2][*][*][#] sequence deletes the previously saved SMS center number. 

[0][3][*][*][?][?][?][?][?][?][#] 

– 

SMS password

 (6 characters) required for a remote 

change of the modem format

. Sending to the module of an SMS containing the 

[?][?][?][?][?][?]=NN sequence will change the modem operating format available in the 
GSM telephone. The two NN digits define the format as described in the function 08. Using 
DTMF signals it is possible to program a password comprised of digits only (0...9), while 
using the DLOAD10 program you can program a password comprised of both letters and 
digits. The [0][3][*][*][#] sequence deletes the previously programmed password. 

[0][4][*][*][?][?][?][?][?][?][#] 

 SMS password 

(6 characters) starting connection with 

DLOAD program. The function applies to interaction between the module and the 
INTEGRA/CA-64 alarm control panel. Sending to the module of an SMS containing the 
programmed password makes the control panel call back to the number saved in its 
memory as the "DLOADX telephone"/"DLOAD64 telephone" in order to start the 
downloading function. If the control panel is to call back to another number, the number 
should be put into the SMS content as follows: [?][?][?][?][?][?]=dddd. (password, equality 
sign, telephone number, dot). If the module receives an SMS message initiating 
connection with the INTEGRA control panel and the access from DLOADX program is 
blocked, the module will send a SMS message stating that "Remote access from DloadX 
program is not granted" to the number preprogrammed with function 26.  

Using DTMF signals it is possible to program a password comprised of digits only (0...9), 

while using the DLOAD10 program you can program a password comprised of both letters 
and digits. The [0][4][*][*][#] sequence deletes the previously programmed password. 

[0][5][*][*][?][?][?][?][?][?][#] 

 SMS password 

(6 characters) starting connection with 

GUARD program. The function applies to interaction between the module and the 
INTEGRA/CA-64 alarm control panel. Sending to the module of an SMS containing the 
programmed password makes the control panel call back to the number saved in its 
memory as the "GuardX telephone"/"Guard64 telephone" in order to start the remote 
communication with the GUARDX/GUARD64 program. If the control panel is to call back 
to another number, the number should be put into the SMS content as follows: 

Содержание GSM LT-2

Страница 1: ...COMMUNICATION MODULE GSM LT 2 USER MANUAL Program version 2 12 gsmLT 2_en 10 10...

Страница 2: ...tel 48 58 320 94 00 fax 48 58 320 94 01 Product description Communications module used to simulate PSTN line over GSM network allowing for alarm transmission in case of a failure or lack of telephone...

Страница 3: ...THE INPUTS 8 9 MESSAGING 10 9 1 SMS MESSAGES 11 9 2 CLIP 11 10 TRANSMITTING SMS MESSAGES 12 10 1 DESCRIPTION OF THE PROCEDURE FOR CONVERTING PAGER MESSAGE INTO SMS MESSAGE 12 10 2 SENDING SMS MESSAGES...

Страница 4: ...alarm control panel support of DLOAD64 GUARD64 DLOADX and GUARDX programs Operation with PBX telephone exchanges as an additional subscriber s line Operation based on interaction with the three range...

Страница 5: ...re or insufficient range OC 50 mA R 1 T 1 extension telephone line connection to the alarm control panel or to a telephone set IN1 IN4 inputs The FLT output is a generalized fault indicator It gets ac...

Страница 6: ...Shown symbolically below are single cycles of various LED lighting modes with their meaning described The shaded fields meaning the LED on and the blank fields the LED off LED off module power off no...

Страница 7: ...cinity of electrical installations since this may involve a risk of malfunctioning Pay special attention to how the cable is laid between the module and the telephone terminals of the alarm control pa...

Страница 8: ...digits and special characters The phone number should be dialed just like from a cellular phone as required by the operator of the network into which the telephone is logged It is recommended that th...

Страница 9: ...means of SMS short text messages The SATEL s STAM 1 monitoring station only supports from version 4 07 SMS monitoring related to the input status of the GSM module located on the site e g GSM 4S or GS...

Страница 10: ...ext violation 4 seconds or 4 minutes Controlling the operation of inputs consists in bypassing and unbypassing their operation This control can be performed manually or remotely The manual bypassing o...

Страница 11: ...ple recognizing the password loaded in the module by the function 82 Bypassing IN4 will bypass the supervision of input 4 The module acoustically acknowledges the execution of the function by audible...

Страница 12: ...storation to normal status termination of violation of the input which is not bypassed The messages can be sent maximally to four telephone numbers The messaging can have a form of SMS message or CLIP...

Страница 13: ...rom dialing the number The cellular phone user has an option to early reject the connection but if he carries out this action too early the module will repeat the call Answering the call either by the...

Страница 14: ...alarm control panel and load appropriate text to be sent into the control panel memory The telephone number as programmed in the control panel must consist of 1 The pager station number preprogrammed...

Страница 15: ...ow function 114 is programmed 3 The properly received number is acknowledged in the handset by two beeps generated by the module Lack of acknowledgement or a busy signal means a dialing error and then...

Страница 16: ...inals When connected to the control panel telephone output the GSM LT 2 module will simulate the telephone monitoring station i e the control panel will dial the monitoring station telephone number st...

Страница 17: ...the module to be programmed from a computer The program is designed for IBM PC AT compatible computers It works in any computer hardware configuration in the WINDOWS 9x ME 2000 XP Vista environment I...

Страница 18: ...Open the window with module data by selecting File New device GSM4 LT module in the program menu see Fig 7 Figure 7 2 Enter the options of module communication settings by clicking on the icon or thro...

Страница 19: ...test of the module with cable connected to RS port 12 1 1 GSM LT 2 Tab This tab allows the user to configure the basic working parameters of the module The values shown on Fig 9 are just an example B...

Страница 20: ...e programmed they are not programmed by default Figure 11 shows a view of the GPRS tab The presented values are just examples Full configuration is only possible from a computer with DLOAD10 program i...

Страница 21: ...st correspond to that defined in the monitoring station Station key a sequence of 1 to 12 alphanumeric characters digits letters and special characters which define the key for coding the data to be s...

Страница 22: ...hrough GPRS RS 232 reporting priority if this option is selected monitoring the events of the control panel connected to the module through the RS 232 port will take priority over reporting the GSM LT...

Страница 23: ...2 module programming mode This operation requires entering a six digit access code by default this code is 1 2 3 4 5 6 In case you have forgotten the code after the change you can only view it or rest...

Страница 24: ...sword comprised of digits only 0 9 while using the DLOAD10 program you can program a password comprised of both letters and digits The 0 3 sequence deletes the previously programmed password 0 4 SMS p...

Страница 25: ...is function is not used The 0 7 sequence will delete the number 0 8 modem standard format 2 digits the format in which the module will communicate with the modem of service user computer The format co...

Страница 26: ...start after power up two short and one long SSL PH SIM PIN code required eight short SSSSSSSS no SIM card three long LLL SIM card damaged four beeps of diminishing length LlSs SIM card busy long short...

Страница 27: ...0 test transmission priority This option determines whether the test transmission will override the call being just carried out by the module If yes the current connection will be terminated whenever...

Страница 28: ...will change the parameter programmed with function 21 The new telephone number must be identical in form to that programmed with the appropriate function Using the DTMF signals you can program passwo...

Страница 29: ...the module will automatically bypass input IN2 from 0 to 15 0 no bypassing 5 1 number of violations after which the module will automatically bypass input IN3 from 0 to 15 0 no bypassing 5 2 number of...

Страница 30: ...fied The same settings as for input IN1 6 7 telephone numbers to which the input IN3 violation will be notified The same settings as for input IN1 6 8 telephone numbers to which the input IN4 violatio...

Страница 31: ...messages of any content The sequence 8 1 will delete the SMS code 8 2 DTMF code 4 digits from the 0 9 range for bypassing the input IN1 The sequence 8 2 will delete the code 8 3 DTMF code 4 digits fro...

Страница 32: ...1 Editing is similar as in function 06 The control is available after dialing the number which has been programmed here after which you should enter control sequences consisting of the character and...

Страница 33: ...is to be sent as SMS message the number of digits must be within the range of 1 16 The sequence 1 0 7 will delete the number 1 0 8 telephone number to which SMS message whose content can only be enter...

Страница 34: ...after the preprogrammed time from the settings being written to the module has elapsed 1 1 4 a country code prefix added before the cellular phone number to which SMS message is to be sent after recei...

Страница 35: ...IMPORTANT PIN PUK Telephone No...

Страница 36: ...SATEL sp z o o ul Schuberta 79 80 172 Gdansk POLAND tel 48 58 320 94 00 info satel pl www satel eu...