GSM LT-2
SATEL
15
External
modem
and
ISDN/GSM/ETHM modem
options must be enabled on the control
panel side. When working in this configuration, the module only enables monitoring through
GPRS, according to the transmission parameters programmed in the control panel
(the module GPRS settings will be reprogrammed). It is possible to check the connection
between the INTEGRA control panel (in version 1.06 or later) and the module (function 98).
If there is no connection, the module will send information to the monitoring station.
Monitoring the control panel events can take priority over reporting the module status
(function 109).
12. M
ODULE PROGRAMMING
For the module to operate properly, corresponding parameters must be programmed.
The programming is possible by means of a stationary telephone capable of generating
DTMF signals, or by using a PC computer and the DLOAD10 program (version 1.00.29 or
later).
12.1 P
ROGRAMMING USING COMPUTER WITH
DLOAD10
PROGRAM
The GSM LT-2 module is delivered together with the DLOAD10 program which enables the
module to be programmed from a computer.
The program is designed for IBM PC/AT compatible computers. It works in any computer
hardware configuration in the
WINDOWS
(9x/ME/2000/XP/Vista) environment. It is
recommended that the program be installed on the computer hard disk.
The GSM LT-2 module communicates with the computer via the RS-232 interface.
To connect the ports, use the cable made as shown on Fig. 6 (such a cable, designated with
the DB9F/RJ-KPL symbol, is available in the SATEL's offer).
Figure 6. Connection of computer to module serial port
.
For installation of the program run the
setup.exe
program from a CD delivered with the
module.
Having installed the program, start it. Access to the program is protected with an
access
code.
After installation of the program, the access code is:
1234
and can be changed in any
string of 16 alphanumeric characters. As long as the code has its factory setting, pressing the
"ENTER" key (without entering any code) will start the program with the default access code
(1234).
2
4
5
DB-9
3
8
TO MODULE
(view of the
RS-232
port on
the module board)
comp.DTR.
comp.CTS.
comp.TXD.
comp.RXD.
GND
module DSR
module RTS
module RXD
module TXD
GND
TO COMPUTER
(female connectors as
seen from soldering