background image

4 CA-64 

SM 

SATEL 

2.2  Monitoring the recorded voice messages 

1.  Connect the headset to the socket which enables monitoring of the messages. 
2.  Press the MSG. NO button to select the number of message to be played back. The 

message number is displayed by means of LEDs as shown in Table 1. 

3.  Press the PLAY button (the PLAY LED will go on). The message will be played back. 

3. Technical data 

Number of stored voice messages.........................................................................................16 
Maximum message duration ............................................................................................... 15 s 
Supply voltage ................................................................................................... 12 V DC ±15% 
Maximum current consumption ........................................................................................65 mA 
Dimensions of electronics board ............................................................................... 57x80 mm 
Weight.................................................................................................................................41 g 
 
 
 
 
 
 
 
 
 
 
 
 

The latest EC declaration of conformity and product approval certificates are 

available for downloading on website   

www.satel.pl

 

 

 
 
 
 
 
 
 
 

SATEL sp. z o.o. 

ul. Schuberta 79 

80-172 Gda

ń

sk 

POLAND 

tel. + 48 58 320 94 00 

[email protected] 

www.satel.pl 

Содержание CA-64 SM

Страница 1: ...set of DIP switches for setting individual address of the module and for disabling enabling the message recording see section DIP SWITCHES 2 SYSTEM LED indicating communication with the control panel LED is blinking data exchange with the control panel LED is lit no communication with the control panel 3 LEDs to provide information on voice messages M3 M2 M1 M0 present the number of recorded playe...

Страница 2: ...LED ON 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Table 1 The way of message number presentation 1 1 DIP switches The DIP switches from 1 to 5 are to be used for address setting The address must be different from that of the other modules connected to the communication bus of alarm control panel In order to determine the expander address add up the values set on individual switches as shown in Table 2 DIP ...

Страница 3: ...IP switches set the expander address 5 Turn on power supply of the alarm system 6 Start the identification function in the control panel 2 1 Recording the voice messages 1 Set the DIP switch 8 into the ON position 2 Press the MSG NO button to select the number of message to be recorded The message number is displayed by means of LEDs as shown in Table 1 3 Press the REC button the REC LED will go o...

Страница 4: ...he PLAY button the PLAY LED will go on The message will be played back 3 Technical data Number of stored voice messages 16 Maximum message duration 15 s Supply voltage 12 V DC 15 Maximum current consumption 65 mA Dimensions of electronics board 57x80 mm Weight 41 g The latest EC declaration of conformity and product approval certificates are available for downloading on website www satel pl SATEL ...

Отзывы: