background image

2 CA-64 

SM 

SATEL 

6  -  cables for PIN5 type plug for connecting the expander to the appropriate socket on the 

control panel electronics board. 

7  -  headset socket to enable audio monitoring of the recorded messages. 
8  -  headset socket to enable telephone line listen-in functionality. 

Note:

 When interacting with the INTERA 128-WRL control panel, only the signals received 

by the panel can be listen in.  

9 - microphone. 
 

LED status 

 

Message 

number 

M3   M2   M1   M0 

 

 

 

  – LED OFF 

 

 

  – LED ON 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 

 

 

11 

 

 

12 

 

 

13 

 

 

14 

 

 

15 

 

 

Table 1. The way of message number presentation. 

 

1.1 DIP-switches 

The DIP-switches from 1 to 5 are to be used for address setting. The address must be 
different from that of the other modules connected to the communication bus of alarm control 
panel. In order to determine the expander address, add up the values set on individual 
switches as shown in Table 2. 
 

DIP-switch number 

1 2 3 4 5 

Numerical value 

(for switch in ON position)

 

1 2 4 8 16 

Table 2. 

 
The DIP-switch 8 is used to disable/enable the message recording: 

  switch in ON position – message recording available; 

  switch in OFF position – message recording not available. 

Содержание CA-64 SM

Страница 1: ...set of DIP switches for setting individual address of the module and for disabling enabling the message recording see section DIP SWITCHES 2 SYSTEM LED indicating communication with the control panel LED is blinking data exchange with the control panel LED is lit no communication with the control panel 3 LEDs to provide information on voice messages M3 M2 M1 M0 present the number of recorded playe...

Страница 2: ...LED ON 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Table 1 The way of message number presentation 1 1 DIP switches The DIP switches from 1 to 5 are to be used for address setting The address must be different from that of the other modules connected to the communication bus of alarm control panel In order to determine the expander address add up the values set on individual switches as shown in Table 2 DIP ...

Страница 3: ...IP switches set the expander address 5 Turn on power supply of the alarm system 6 Start the identification function in the control panel 2 1 Recording the voice messages 1 Set the DIP switch 8 into the ON position 2 Press the MSG NO button to select the number of message to be recorded The message number is displayed by means of LEDs as shown in Table 1 3 Press the REC button the REC LED will go o...

Страница 4: ...he PLAY button the PLAY LED will go on The message will be played back 3 Technical data Number of stored voice messages 16 Maximum message duration 15 s Supply voltage 12 V DC 15 Maximum current consumption 65 mA Dimensions of electronics board 57x80 mm Weight 41 g The latest EC declaration of conformity and product approval certificates are available for downloading on website www satel pl SATEL ...

Отзывы: