background image

 

 

 

 
 
 
 
 

ASW-210 

 

Flush-mounted wireless two-channel 

230 V AC controller 

 

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 

 

Firmware version 1.00 

asw-210_en 07/19 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Содержание ASW-210

Страница 1: ...ASW 210 Flush mounted wireless two channel 230 V AC controller Firmware version 1 00 asw 210_en 07 19 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Страница 2: ...e of the device is located on the enclosure base SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type ASW 210 is in compliance with Dir...

Страница 3: ... the controller outputs 2 programmable wired inputs support for NO or NC type switches Encrypted two way radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission without interference with other signals in the 868 MHz frequency band ABAX 2 system only Remote update ...

Страница 4: ...hase wire NO1 gray NO contact of the relay output 1 normally it is disconnected from the common contact C does not conduct electricity NO2 black NO contact of the relay output 2 normally it is disconnected from the common contact C does not conduct electricity C red common contact C of the relay outputs Terminals SW1 SW2 control input NO N for connecting 230 V AC supply neutral wire Radio communic...

Страница 5: ...a risk of electric shock and may damage the module The wired inputs of the controller are not galvanically isolated It is not recommended to use the controller to switch the capacitive loads e g LED lighting power supply units LED lamps more frequently than every 10 seconds Do not connect more than one LED lighting power supply to the relay output The ASW 210 controller is designed for mounting in...

Страница 6: ...e ASW 210 controller and check if it improves the signal strength The controller can be installed in the selected junction box if the signal strength is higher than 40 9 Power off the circuit to which the controller is connected 10 Open the junction box and remove the controller 11 Connect the wires of controller relay outputs to the wires of electrical circuits to be controlled by the controller ...

Страница 7: ...SATEL ASW 210 5 ...