background image

4 ASW-210 

SATEL 

6.  Add the ASW-210 controller to the wireless system and configure its settings (see 

ABAX 2 controller manual or INTEGRA 128-WRL control panel manual).

 

The sticker with 

serial number which shall be entered when registering the detector in the system can be 
found on the enclosure. 

If the ABAX 2 / ABAX controller is connected to the VERSA / VERSA Plus / VERSA IP 
control panel, use the DLOADX program to add and configure the ASW-210 controller. 

Simultaneous operation of the ASW-210 controller by the ABAX 2 and ABAX controller 
/ INTEGRA 128-WRL alarm control panel is not possible. 

7.  Close the junction box. 
8.  Check the level of radio signal received from ASW-210 controller by the ABAX 2 / ABAX 

controller / control panel. If it is low, try to move around the ASW-210 controller and 
check if it improves the signal strength. The controller can be installed in the selected 
junction box if the signal strength is higher than 40%. 

9.  Power off the circuit to which the controller is connected. 
10. Open the junction box and remove the controller. 
11. Connect the wires of controller relay outputs to the wires of electrical circuits to be 

controlled by the controller (Fig. 2).  

Given the specific character of radio communication, it is not recommended that the 
controller be used in applications where quick switching of the output status is 
expected. 

12. Connect switches to the controller inputs (Fig. 2). To make connections, use flexible 

wires with a cross-sectional area of 0.5-0.75 mm

2

13. Mount the controller in the junction box. Make sure the electric wires are behind the 

controller enclosure. 

14. Close the junction box. 
15. Power on the circuit to which the controller is connected. 
16. Check the controller for proper functioning. 

 

Содержание ASW-210

Страница 1: ...ASW 210 Flush mounted wireless two channel 230 V AC controller Firmware version 1 00 asw 210_en 07 19 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Страница 2: ...e of the device is located on the enclosure base SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type ASW 210 is in compliance with Dir...

Страница 3: ... the controller outputs 2 programmable wired inputs support for NO or NC type switches Encrypted two way radio communication in the 868 MHz frequency band AES standard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission without interference with other signals in the 868 MHz frequency band ABAX 2 system only Remote update ...

Страница 4: ...hase wire NO1 gray NO contact of the relay output 1 normally it is disconnected from the common contact C does not conduct electricity NO2 black NO contact of the relay output 2 normally it is disconnected from the common contact C does not conduct electricity C red common contact C of the relay outputs Terminals SW1 SW2 control input NO N for connecting 230 V AC supply neutral wire Radio communic...

Страница 5: ...a risk of electric shock and may damage the module The wired inputs of the controller are not galvanically isolated It is not recommended to use the controller to switch the capacitive loads e g LED lighting power supply units LED lamps more frequently than every 10 seconds Do not connect more than one LED lighting power supply to the relay output The ASW 210 controller is designed for mounting in...

Страница 6: ...e ASW 210 controller and check if it improves the signal strength The controller can be installed in the selected junction box if the signal strength is higher than 40 9 Power off the circuit to which the controller is connected 10 Open the junction box and remove the controller 11 Connect the wires of controller relay outputs to the wires of electrical circuits to be controlled by the controller ...

Страница 7: ...SATEL ASW 210 5 ...