LIMITED WARRANTY

 

The manufacturer offers the customer a 24-month functional warranty on 
the instrument for faulty workmanship or parts from date of dispatch from 
the distributor. In all cases, this warranty is valid for 36 months from the 
date of production. This warranty is on a return to factory basis. 
The manufacturer does not accept liability for any damage caused by 
instrument malfunction. The manufacturer accepts no responsibility for 
the suitability of the instrument to the application for which it was 
purchased. 
Failure to install, setup or operate the instrument according to the 
instructions herein will void the warranty. 
Your instrument may be opened only by a duly authorized representative 
of the manufacturer. The unit should only be opened in a fully anti-static 
environment. Failure to do so may damage the electronic components 
and will void the warranty. 

NOTE 

The greatest care has been taken to manufacture your instrument. 
However, these instructions do not cover all possible contingencies that 
may arise during installation, operation or maintenance, and not all 
details and variations of this equipment are covered by these 
instructions.   
For additional information regarding installation, operation or 
maintenance of this instrument, contact the manufacturer or your local 
representative or distributor. 

Table of Contents 

1

 

Mechanical Installation _____________________ 3

 

1.1

 

Standard Cutouts (round or square) __________________ 3

 

1.2

 

Special Cutouts ___________________________________ 4

 

2

 

Electrical Installation _______________________ 5

 

3

 

Setup on the RDM _________________________ 6

 

3.1

 

Instrument Setup Menus____________________________ 6

 

3.2

 

Performing RDM  Communication Adjustment _________ 6

 

3.3

 

RDM Setup Menu __________________________________ 6

 

4

 

Status Information Menu____________________ 8

 

5

 

Troubleshooting: Fault Condition Display _____ 9

 

6     Communications __________________________ 9

 

 

 

BG0324  Rev. A2

 

Содержание RDM172

Страница 1: ...RDM172 Remote Display Module QUICK GUIDE BG0324 Rev A2 ...

Страница 2: ...al injury and or equipment damage 2 Before connecting the instrument to the power source check that your power supply has 12V 15 voltage and 350mA current 3 Under no circumstances should the instrument be connected to a power source if it is damaged 4 To prevent potential fire or shock hazard do not expose the instrument to rain or moisture 5 Mount the instrument away from heat sources in a dirt f...

Страница 3: ...warranty NOTE The greatest care has been taken to manufacture your instrument However these instructions do not cover all possible contingencies that may arise during installation operation or maintenance and not all details and variations of this equipment are covered by these instructions For additional information regarding installation operation or maintenance of this instrument contact the ma...

Страница 4: ...3 1 Mechanical Installation 1 1 Standard Cutouts round or square Figure 1 1 RDM172 Cutout Dimensions Figure 1 2 RDM172 Mounting STEP 1 Insert RDM into cut out STEP 2 Fasten washers and nut on screws ...

Страница 5: ...4 1 2 Special Cutouts Figure 1 3 Panel Cutout Dimensions Figure 1 4 RDM172 Mounting ...

Страница 6: ...he PM172 via terminals as shown in Figure 2 1 One RDM unit can be connected in multi drop mode to up to 32 PM172 instruments Figure 2 1 RDM172 Electrical Connections IMPORTANT It is recommended to solder the wire ends before attaching them to the connectors ...

Страница 7: ...ee the complete PM172 Installation and Operation Manual 3 2 Performing RDM Communication Adjustment Î Î Î Î Press to activate middle window Press and scroll to Addr Press to activate the lower window Set the instrument address value and press to save the selected value Press and scroll to bAud Press to activate the lower window Set the baud rate value and press to save the selected value 3 3 RDM S...

Страница 8: ...ted use VoLt Primary or secondary voltage view Pri SEc Defines primary or secondary voltage to show Ph P Phase powers display mode diS En Disables enables display of phase powers in common measurements main screen Fund Fundamenta l values display mode diS En Disables enables display of fundamental values in common measurements main screen dAtE Date format ndY dnY Ynd Defines the date format in the...

Страница 9: ...follows 1 upper window 2 middle window 3 lower window Table 4 1 Page Window Parameter Digits Unit 1 1 PHAS Label 1 2 rOt Label 1 3 Phase rotation POS NEG ERR 4 2 1 rEL Label 2 2 1 2 Label 2 3 Relay status 1 2 2 3 1 St In Label 3 2 1 2 Label 3 3 Status inputs 1 2 2 4 1 Cnt 1 Label 4 3 Counter 1 6 5 1 Cnt 2 Label 5 3 Counter 2 6 6 1 Cnt 3 Label 6 3 Counter 3 6 7 1 Cnt 4 Label 7 3 Counter 4 6 8 1 bAt...

Страница 10: ...ation setup changed RDM172 communication setup changed Press to check or alter the RDM172 adjustment and scroll to communication options 6 Communications NOTE Where an RS 232 RS 422 converter is used R1 is not applicable since it is built in to the converter Use a shielded 0 33 mm 2 22 AWG twisted pair cable for each communication link terminate the ends of multi drop line with 200 500 Ohm resisto...

Отзывы: