RDM172 Remote Display Module

    

QUICK GUIDE

 

The RDM172 is an optional remote display for the PM172 Powermeter. 
It features a bright LED display (3 windows with 6 LEDs each), 18 LED 
indicators, two communication receive/transmit LEDs, 6 control push-
buttons, and a communication port (RS-485). The RDM172 uses the 
Modbus RTU transmission protocol for communication with the PM172 
and acts as the Master.  

 

The RDM172 offers approximately the same functions as the PM172 
front panel, and supports both the PM172P and PM172E models without 
additional adjustment. See the 

PM172 Installation and Operation Manual

 

for information on the display panel.

 

IMPORTANT 

Please read instructions contained in this manual before 
performing installation, and take note of the following precautions: 

1. 

Ensure that the incoming DC power source is turned OFF

 

before performing any work on the instrument.  Failure to do so 
may result in serious or even fatal injury and/or equipment damage. 

2.  

Before connecting the instrument to the power source, check 

that your power supply has 12V ±15% voltage and 350mA current.  

3.  

Under no circumstances should the instrument be connected 
to a 

power source if it is damaged. 

4.  

To prevent potential fire or shock hazard, do not expose the 
instrument

 to rain or moisture. 

5.  

Mount the instrument away from heat sources in a dirt-free 
environment.

 Do not operate the instrument in direct sunlight. 

6.  

Setup procedures must be performed only by qualified 
personnel 

familiar with the

 

instrument and its associated electrical 

equipment. 

7.  

DO NOT attempt to open the instrument under any 
circumstances. 

8.  

Although designed to operate in an electrically noisy 
environment, 

the instrument should not be placed near very high 

electric fields. In the event that the instrument is mounted in a 
harsh, noisy environment with high potential for electromagnetic 
impulses from heavy switch gears, motors or lightning, it is 
recommended to install appropriate protective devices such as 
lightening and over-voltage arresters to incoming voltage and 
communication inputs. 

 

Содержание RDM172

Страница 1: ...RDM172 Remote Display Module QUICK GUIDE BG0324 Rev A2 ...

Страница 2: ...al injury and or equipment damage 2 Before connecting the instrument to the power source check that your power supply has 12V 15 voltage and 350mA current 3 Under no circumstances should the instrument be connected to a power source if it is damaged 4 To prevent potential fire or shock hazard do not expose the instrument to rain or moisture 5 Mount the instrument away from heat sources in a dirt f...

Страница 3: ...warranty NOTE The greatest care has been taken to manufacture your instrument However these instructions do not cover all possible contingencies that may arise during installation operation or maintenance and not all details and variations of this equipment are covered by these instructions For additional information regarding installation operation or maintenance of this instrument contact the ma...

Страница 4: ...3 1 Mechanical Installation 1 1 Standard Cutouts round or square Figure 1 1 RDM172 Cutout Dimensions Figure 1 2 RDM172 Mounting STEP 1 Insert RDM into cut out STEP 2 Fasten washers and nut on screws ...

Страница 5: ...4 1 2 Special Cutouts Figure 1 3 Panel Cutout Dimensions Figure 1 4 RDM172 Mounting ...

Страница 6: ...he PM172 via terminals as shown in Figure 2 1 One RDM unit can be connected in multi drop mode to up to 32 PM172 instruments Figure 2 1 RDM172 Electrical Connections IMPORTANT It is recommended to solder the wire ends before attaching them to the connectors ...

Страница 7: ...ee the complete PM172 Installation and Operation Manual 3 2 Performing RDM Communication Adjustment Î Î Î Î Press to activate middle window Press and scroll to Addr Press to activate the lower window Set the instrument address value and press to save the selected value Press and scroll to bAud Press to activate the lower window Set the baud rate value and press to save the selected value 3 3 RDM S...

Страница 8: ...ted use VoLt Primary or secondary voltage view Pri SEc Defines primary or secondary voltage to show Ph P Phase powers display mode diS En Disables enables display of phase powers in common measurements main screen Fund Fundamenta l values display mode diS En Disables enables display of fundamental values in common measurements main screen dAtE Date format ndY dnY Ynd Defines the date format in the...

Страница 9: ...follows 1 upper window 2 middle window 3 lower window Table 4 1 Page Window Parameter Digits Unit 1 1 PHAS Label 1 2 rOt Label 1 3 Phase rotation POS NEG ERR 4 2 1 rEL Label 2 2 1 2 Label 2 3 Relay status 1 2 2 3 1 St In Label 3 2 1 2 Label 3 3 Status inputs 1 2 2 4 1 Cnt 1 Label 4 3 Counter 1 6 5 1 Cnt 2 Label 5 3 Counter 2 6 6 1 Cnt 3 Label 6 3 Counter 3 6 7 1 Cnt 4 Label 7 3 Counter 4 6 8 1 bAt...

Страница 10: ...ation setup changed RDM172 communication setup changed Press to check or alter the RDM172 adjustment and scroll to communication options 6 Communications NOTE Where an RS 232 RS 422 converter is used R1 is not applicable since it is built in to the converter Use a shielded 0 33 mm 2 22 AWG twisted pair cable for each communication link terminate the ends of multi drop line with 200 500 Ohm resisto...

Отзывы: