![SATA STEAMaster+ SERIES Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/sata/steamaster-series/steamaster-series_installation-operation-and-maintenance-manual_1200053021.webp)
(
06/06
)
STEA
SERIES
Installation, Operation & Maintenance Manual
21
The HumiControl Controller
1: PRG
- Access to most frequently used parameters.
Also resets alarm relay.
2: SEL
- Displays unit of measure. Press for 2
seconds to access set point. Press with PRG for 5
seconds to enter parameters.
3:
Ç
-
Displays control sensor value. In programming
mode increases value or moves to previous parameter.
4:
È
-
Displays high limit sensor value. In program-
ming mode decreases value or moves to following
parameter.
5:
2-1/2 digit display for values and parameters.
6:
LED to indicate decimal point.
7:
LED to indicate value must be multiplied by
1000.
8:
LED to indicate dehumidify mode.
9:
LED to indicate alarm.
10:
LED to indicate humidifier is producing steam.
Flashing indicates lower than required production.
11:
LED to indicate when unit is filling.
12:
LED to indicate when unit is draining.
Start-up Procedure
After closing the external fused disconnect to put power to the humidifier, press the top (I) part
of the I/O switch on the side of the unit
Initially, all LEDs light - this lasts about 1-2 seconds.
Then the initialization phase begins with 3 dashes. During this phase
diagnostics are conducted. This phase lasts about 4 seconds.
After running the diagnostics, the unit will start operation and display either
the % of steam production (On/off and Modulating modes), the %RH
(Stand-Alone Modulating mode), or two dashes will light, indicating the
humidifier is disabled or in alarm. The alarm code will flash.
Starting with a new cylinder
When starting with a new cylinder, you should activate the cylinder cleaning function by pressing the
SEL
and
È
È
È
È
È
buttons simultaneously for 2 seconds after the initialization phase. This forces the unit to open both the drain and
fill valves for 10 minutes to flush the lines, then fills and drains the cylinder 3 times to wash out any mold release or
dirt. Once started, this function can be stopped by pressing the
SEL
and
È
È
È
È
È
buttons simultaneously for 2 seconds
again.
When starting the unit with a new or empty cylinder, it may take a significant amount of time (hours) for
the unit to build up enough mineral concentration to reach rated capacity. This time can be shortened
by the addition of Alka-Seltzer or salt (teaspoon) through the steam outlet on top of the cylinder.