STEA
SERIES
Installation, Operation & Maintenance Manual
13
Single Phase Terminals
Three Phase Terminals
Power wiring
Check that the power supply voltage to be
connected matches the value indicated on the
rating plate inside the electrical panel. Insert
the power and ground connection cables into
the electrical panel compartment using the
strain reliefs supplied, and connect to the
terminals. An external fused disconnect must
be installed.
All wiring must be in accordance with local, state
and national electric codes.
NOTE:
to avoid unwanted interference, the
power cables should be kept separate from any
control wiring.
Per the table on the following page, make sure
that the unit has the proper number of turns
through the TAM (Torroid Amperage Monitor),
which is on the control board in models
SMP001 through SMP015, and separate in
models SMP025 through SMP065. Also make
sure that the TA Rate DIP switches on the
control board are set correctly per the table.
In models SMP001 - SMP015 make sure that the TAM on
the circuit board has the proper number of power wire
turns through it, and that the TA Rate DIP switches on the
control board are set per the table on the following page.
In models SMP025 - SMP065 the TAM is independent and the jumper must then be on the right terminals per the
table on the following page.