background image

III.13

EN

Operating instructions SATAjet  4000-110/-120 (DIGITAL)

Operating instructions SATAjet  4000-110/-120 (DIGITAL)

Malfunction

Cause

Corrective Action

Air bubbles appearing 

in the gravity flow cup

Loose air cap 

Tighten air cap 

[2-2] 

by hand

Gap between air cap 

and fluid tip ("air cir

-

cuit") is clogged

Clean air circuit, ob-

serve chapter 8

Nozzle set is clogged 

or damaged

Clean nozzle set, 

chapter 8, or replace, 

respectively, chapter 

9.1

Not enough paint ma-

terial in the gravity flow 

cup

Refill gravity flow cup 

[1-6]

Defective paint needle 

sealing 

Replace the paint nee-

dle sealing, chapter 

9.3

Spray pattern is too 

small, crooked, lop-

sided or splitting

Clogged air cap drill-

ings 

Clean air cap, observe 

chapter 8

Damaged fluid tip (fluid 

tip aperture) 

Check if fluid tip is 

damaged, replace the 

nozzle set, if neces-

sary, chapter 9.1

No function of round/

flat spray control - con

-

trol knob can still be 

turned

Air distribution ring has 

not been positioned in 

correct location (pin is 

not located in the drill-

ing) or damaged

Replace air distribution 

ring making sure it has 

been positioned cor-

rectly when inserting it, 

chapter 9.2

Round/flat spray con

-

trol cannot be regu-

lated

Control has been 

turned too much in 

counterclockwise di-

rection; spindle has 

loosend inside the 

spray gun thread 

Remove control with 

universal spanner; 

rectify or replace com-

pletely, chapter 9.6

EN-Content-BAL-SATAjet 4000 -110 -120.indd   13

29.10.2012   13:43:42

Содержание SATAjet 4000 Series

Страница 1: ...SATAjet 4000 110 120 Betriebsanleitung Operating Instructions Intro BAL SATAjet 4000 110 120 indd 1 25 10 2012 14 59 10...

Страница 2: ...Betriebsanleitung deutsch I A DE II CN Operating Instructions english III EN IRL Index intro_jet4000B indd 2 31 10 2012 11 35 01...

Страница 3: ...1 1 7 1 9 1 3 1 11 1 12 1 13 1 14 1 15 1 1 1 2 1 4 1 8 1 18 1 19 1 5 1 10 1 16 1 17 1 6 Design US D644 716S Intro BAL SATAjet 4000 110 120 indd 3 25 10 2012 14 59 11...

Страница 4: ...2 2 2 2 1 2 4 2 3 2 5 2 7 2 8 2 9 2 6 2 10 2 11 2 12 2 13 2 14 16S Intro BAL SATAjet 4000 110 120 indd 4 25 10 2012 14 59 12...

Страница 5: ...vor Gefahr die zum Tode oder zu schweren Verletzungen f hren kann Vorsicht vor gef hrlicher Situation die zu Sachsch den f hren kann Explosionsgefahr Warnung vor Gefahr die zum Tode oder zu schweren V...

Страница 6: ...Drehgelenk 11 g 8 g Druckluftanschluss G 1 4 F llmenge Flie becher Kunststoff 600 ml Optional elektronische Druckmesseinrichtung Ein Ausschaltschwelle 0 2 bar Anzeigegenauigkeit 0 05 bar Maximaler Anz...

Страница 7: ...hluss 1 17 ColorCode System CCS 1 18 Frontplatte f r Druckanzeige nur bei DIGITAL 1 19 Druckanzeige nur bei DIGITAL 5 Bestimmungsgem e Verwendung Die Lackierpistole ist bestimmungsgem vorgesehen zum A...

Страница 8: ...berpr fen und ggf instand set zen Lackierpistole bei Besch digung sofort au er Betrieb nehmen vom Druckluftnetz trennen Lackierpistole niemals eigenm chtig umbauen oder technisch ver n dern Ausschlie...

Страница 9: ...kr fte sind gering 6 4 Verwendung in explosionsgef hrdeten Berei chen Ex Zeichen Ger tegruppe Ger tekategorie Kategorie Gas Temperaturklasse 6 4 1 Allgemein Die Lackierpistole ist zur Verwendung Aufbe...

Страница 10: ...eriewechsel innerhalb explosionsgef hrdeter Bereiche ffnen der Frontplatte f r Druckanzeige Einbau einer anderen Batterie als CR 1632 Fa Renata Das Wechseln der Dichtung am Batteriefach wird bei Batte...

Страница 11: ...weis Abzugsb gel voll abziehen und Pistoleneingangsdruck siehe Kapitel 2 gem einem der folgenden Abschnitte 3 1 3 2 3 3 3 4 bis 3 5 einstellen Abzugsb gel wieder loslassen Bei 3 3 3 4 und 3 5 muss der...

Страница 12: ...der Lackierpistole Warnung Vorsicht Vor allen Reinigungsarbeiten Lackierpistole vom Druckluftnetz abkop peln Verletzungsgefahr durch unerwarteten Druckluftaustritt und oder Austritt des Spritzmediums...

Страница 13: ...ie Dauer des Waschvorgangs in der Waschmaschine belassen Niemals Ultraschallreinigungssysteme verwenden Besch di gungen von D sen und Oberfl chen Nach dem Reinigen Lackierpistole und Farbkanal Luftd s...

Страница 14: ...2 ggf reinigen Bei Besch digung wenden Sie sich bitte an Ihren SATA H nd ler Neuen Luftverteilerring anhand der Markierung 8 3 positionieren Zapfen in Bohrung und gleichm ig einpressen Nach dem Einbau...

Страница 15: ...der selbstnachstellenden Dichtung 10 5 ist erforderlich wenn Luft unter dem Abzugsb gel austritt 1 Nach Demontage Luftkolbenstange 10 4 berpr fen ggf reinigen oder bei Besch digung z B Kratzer oder v...

Страница 16: ...c Knopf 11 2 entsprechend Bild positionieren Linie in Knopf senk recht Schraube 11 1 Torx T20 in Knopf handfest einschrauben dabei Knopf in Position festhalten 9 8 Batterie DIGITAL ersetzen 12 1 und 1...

Страница 17: ...r schmutzt oder besch digt D sensatz reinigen Kapitel 8 bzw tau schen Kapitel 9 1 Zu wenig Spritzmedi um im Flie becher Flie becher 1 6 nachf llen Farbnadeldichtung defekt Farbnadeldichtung tau schen...

Страница 18: ...zu lange in an der Pistole Reinigung Kapitel 8 beachten Pistolen k rper austauschen lassen Ungeeignete Reini gungsfl ssigkeiten Digitalanzeige schwarz Pistole zu lange in Reinigungsfl ssigkeit Reinig...

Страница 19: ...des Produkts Einsatz von nicht ausgebildetem Personal Nichtverwendung von pers nlicher Schutzausr stung Nichtverwendung von Original Zubeh r und Ersatzteilen Eigenm chtigen Umbauten oder technischen...

Страница 20: ...tverteilerringen 165977 Abzugsb gelset f r SATAjet 4000 165985 Dichtungshalter mit H lse f r SATAjet 4000 DIGITAL 165993 Batterieset mit Verschlussschraube und Dichtung f r DIGITAL Einrichtung 166009...

Страница 21: ...explosionsgef hrdeten Bereichen EG Maschinenrichtlinie 98 37 EG bis 28 Dezember 2009 EG Maschinenrichtlinie 2006 42 EG Angewandte harmonisierte Normen DIN EN 1127 1 2008 Explosionsschutz Teil 1 Grund...

Страница 22: ...sanleitung SATAjet 4000 110 120 DIGITAL 70023722 f r 10 Jahre hinterlegt 70806 Kornwestheim den 03 04 2012 Albrecht Kruse Gesch ftsf hrer SATA GmbH Co KG Content BAL SATAjet 4000 110 120 indd 18 29 10...

Страница 23: ...3 7 5 8 7 9 8 10 11 11 12 12 12 13 12 14 13 15 14 1 2 110 2 0 bar 2 2 bar 120 2 0 bar Compliant 2 0 bar 0 7 bar 110 17 cm 21 cm 120 10 cm 15 cm 10 0 bar 2 0 bar 110 285 Nl min 120 430 Nl min CN CN Co...

Страница 24: ...C 440 g 462 g RPS 0 6 l 491 g 513 g 0 6 l 612 g 634 g 1 0 l 636 g 658 g RPS 0 6 l 531 g adam 2 513 g 11 g 8 g G 1 4 600 ml 0 2 bar 0 05 bar 9 5 bar Renata CR1632 165993 3 CCS CN Content BAL SATAjet 4...

Страница 25: ...SATAjet 4000 110 120 DIGITAL 4 1 1 1 1 2 1 3 1 4 QCC 1 5 QCC 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 CCS 1 18 1 19 5 6 6 1 6 2 CN Content BAL SATAjet 4000 110 120 indd 3 29 10 2012 13...

Страница 26: ...II 4 CN SATAjet 4000 110 120 DIGITAL 1 14 SATA SATA 6 3 85 dB A 6 4 6 4 1 1 2 CN Content BAL SATAjet 4000 110 120 indd 4 29 10 2012 13 45 31...

Страница 27: ...4 9 EG II 2 G Ex ia IIC T4 Gb FM Global IS CL I ZN 1 AEx ia IIC T4 IS CL I DIV 1 GP A B C D T4 60 C 1 2 KEMA 05 ATEX 1090 X Renata CR 1632 7 10 bar 53090 G 1 4 a SATA 2 92320 SATA 484 CN Content BAL S...

Страница 28: ...2 2 3 2 4 2 5 7 4 14 Nm 2 1 10 1 2 5 2 2 6 8 3 2 7 2 8 4 2 9 2 10 5 20 mm 2 11 2 12 6 2 13 7 2 14 7 1 3 1 3 2 3 3 3 4 3 5 2 3 3 3 4 3 5 1 13 3 1 3 2 SATA adam 2 3 3 3 4 3 5 10 m 9 mm 0 6 bar CN Conte...

Страница 29: ...II 7 CN SATAjet 4000 110 120 DIGITAL 7 2 4 1 4 2 4 3 4 4 7 3 5 1 5 2 7 4 6 1 6 2 2 8 pH 6 8 SATA SATA 64030 SATA CN Content BAL SATAjet 4000 110 120 indd 7 29 10 2012 13 45 31...

Страница 30: ...t 4000 110 120 DIGITAL www sata com TV 9 9 1 7 1 7 2 7 3 7 4 7 5 7 6 SATA 7 1 7 2 7 3 7 2 9 2 7 1 7 2 7 3 8 1 8 2 8 3 7 4 7 5 7 6 SATA 8 2 SATA 8 3 7 2 CN Content BAL SATAjet 4000 110 120 indd 8 29 10...

Страница 31: ...t 4000 110 120 DIGITAL 9 3 9 1 9 2 9 3 9 2 7 2 9 4 10 1 10 2 10 3 SATA 48173 10 1 7 2 9 5 9 1 9 2 10 1 10 2 10 3 10 4 10 5 10 5 1 10 4 SATA 48173 2 7 2 CN Content BAL SATAjet 4000 110 120 indd 9 29 10...

Страница 32: ...ITAL 9 6 CCS 10 6 CCS 9 7 11 1 11 2 11 3 1 a 11 1 Torx T20 11 2 14 11 3 2 a b 11 3 6 11 4 11 3 6 3 c 11 2 11 1 Torx T20 9 8 12 1 12 2 6 4 2 1 3 2 3 0 2 bar 3 psi 165993 CN Content BAL SATAjet 4000 110...

Страница 33: ...II 11 CN SATAjet 4000 110 120 DIGITAL 10 2 1 2 2 8 8 9 1 1 6 9 3 8 9 1 9 2 9 6 9 4 CN Content BAL SATAjet 4000 110 120 indd 11 29 10 2012 13 45 32...

Страница 34: ...II 12 CN SATAjet 4000 110 120 DIGITAL 8 8 9 3 9 1 9 3 8 9 11 12 SATA 13 SATA SATA CN Content BAL SATAjet 4000 110 120 indd 12 29 10 2012 13 45 32...

Страница 35: ...l QCC 49395 0 6 l 76018 10 x 10 76026 50 x 10 86843 133934 3 133942 133959 3 3 133967 3 SATA 133991 3 134098 G 1 4 M15 x 1 140582 5 165928 4 CCS 165936 165944 165951 3 165977 SATAjet 4000 165985 SATA...

Страница 36: ...EG 94 9 EG ATEX X B SATAjet 4000 110 120 DIGITAL ATEX II 2 G T4 0344 KEMA 05 ATEX 1090 IECEx KEM 09 0075X DEKRA Certification B V Utrechtseweg 310 6812 AR Arnhem EN 60079 0 2009 EN 60079 11 2007 EN 6...

Страница 37: ...0 110 120 DIGITAL DIN EN ISO 12100 1 2 DIN EN 1953 1998 DIN 31000 1979 DIN 31001 1 1983 94 9 EG VIII 0123 70023722 10 70806 3 Albrecht Kruse SATA GmbH Co KG CN Content BAL SATAjet 4000 110 120 indd 15...

Страница 38: ...BAL_jet4000_2 indd 18 29 10 2012 12 23 01...

Страница 39: ...which could cause heavy injuries or death Warning Risk which could cause damage Explosion risk Warning against risk which could cause heavy injuries or death Notice Useful tips and recommendations 2 T...

Страница 40: ...11 g 8 g Compressed air connection G 1 4 Capacity of PVC gravity flow cup 600 ml Optional electronic pressure gauge On Off threshold 0 2 bar Display accuracy 0 05 bar Maximum display value 9 5 bar Bat...

Страница 41: ...w 1 15 Air piston not visible 1 16 Compressed air connection 1 17 ColorCode System CCS 1 18 Front cover of the pressure display only with DIGITAL 1 19 Pressure display only with DIGITAL 5 Intended Use...

Страница 42: ...from the compressed air circuit Never manipulate or technically modify the spray gun Use original SATA spare parts and accessories only Exclusively use spray gun washing machines recommended by SATA P...

Страница 43: ...nd are therefore prohibited Use of the spray gun in explosive areas belonging to ex zone 0 Do not use solvents and cleaning agents based on halogenised hydrocarbons Chemical reaction which may occur w...

Страница 44: ...ts must be fulfilled Use a compressed air connection G 1 4 a or a suitable SATA connec tion nipple Ensure minimum compressed air volume air consumption and pres sure recommended spray gun inlet pressu...

Страница 45: ...forces 3 1 Paint spray gun with digital pressure display accurate method 3 2 SATA adam 2 accessory accurate method 3 3 Separate gauge with control device accessory 3 4 Separate gauge without control d...

Страница 46: ...able regenerates or other aggressive cleaning solutions Do not soak spray gun in cleaning solution Do not clean cover plate of the electronic pressure display with pointed sharp or rough objects Drill...

Страница 47: ...ay gun from the compressed air circuit Disassemble and install components very carefully Exclusively use included special tools 9 1 Replacing the Nozzle Set 7 1 7 2 7 3 7 4 7 5 and 7 6 Every SATA nozz...

Страница 48: ...heck if paint needle is damaged or replace the nozzle set if required Adjust material flow according to chapter 7 2 after installation 9 4 Replacing the Air Piston Air Piston Spring and Air Micrometer...

Страница 49: ...st material flow according to chapter 7 2 Warning Check if locking screw has been firmly tightened Air micrometer could shoot out from the spray gun uncontrolled 9 6 Replace CCS ColorCode System The C...

Страница 50: ...ears When the battery symbol appears on the pressure display the battery has to be exchanged within the next 2 to 3 weeks The battery is empty when no pressure is indicated with the spray gun inlet pr...

Страница 51: ...splitting Clogged air cap drill ings Clean air cap observe chapter 8 Damaged fluid tip fluid tip aperture Check if fluid tip is damaged replace the nozzle set if neces sary chapter 9 1 No function of...

Страница 52: ...device required Wrong positionining of the spray gun inside the gun washing ma chine Material leaks from behind the paint nee dle sealing Defective or missing paint needle sealing Replace insert pain...

Страница 53: ...When the product is manipulated tampered with or technically modi fied In case of normal wear and tear In case when the product has been exposed to untypical shockloads and impacts during usage Assemb...

Страница 54: ...sleeve kit 166017 Air micrometer aif flow control knob 166025 Material flow control with counter nut 166033 Control knob and screw 2 pieces each 166116 Air connection for SATAjet 4000 DIGITAL with sl...

Страница 55: ...rdeten Bereichen Teil 1 Grundlagen und Anforderun gen Non electronic Devices for the Use in Explosive Areas Part 1 Basics and Requirements DIN EN ISO 12100 1 2 Sicherheit von Maschinen Allgemeine An f...

Страница 56: ...ting instructions SATAjet 4000 110 120 DIGITAL documentation number 70023722 70806 Kornwestheim April 03 2012 Albrecht Kruse President SATA GmbH Co KG EN Content BAL SATAjet 4000 110 120 indd 18 29 10...

Страница 57: ...3 3 5 3 3 3 4 3 2 3 1 Outro BAL SATAjet 4000 110 120 indd 57 24 10 2012 15 05 50...

Страница 58: ...4 5 6 4 3 4 4 6 1 4 1 5 1 5 2 0 0 90 90 6 2 6 2 4 2 Outro BAL SATAjet 4000 110 120 indd 58 24 10 2012 15 05 53...

Страница 59: ...7 8 7 2 7 3 7 1 7 5 7 4 7 6 14 Nm 8 1 8 2 8 3 Outro BAL SATAjet 4000 110 120 indd 59 24 10 2012 15 05 56...

Страница 60: ...9 9 1 9 3 9 2 1 2 3 Outro BAL SATAjet 4000 110 120 indd 60 24 10 2012 15 06 00...

Страница 61: ...10 10 1 10 2 10 4 10 5 10 3 10 6 Outro BAL SATAjet 4000 110 120 indd 53 24 10 2012 15 05 41...

Страница 62: ...11 12 12 1 12 2 a c b 11 1 11 2 11 1 11 2 11 3 11 4 Outro BAL SATAjet 4000 110 120 indd 54 24 10 2012 15 05 44...

Страница 63: ...13 14 Outro BAL SATAjet 4000 110 120 indd 55 24 10 2012 15 05 46...

Страница 64: ...14 4024 20 SATA GmbH Co KG Domertalstra e 20 70806 Kornwestheim Deutschland Tel 49 7154 811 0 Fax 49 7154 811 196 E Mail info sata com www sata com Outro BAL SATAjet 4000 110 120 indd 56 24 10 2012 15...

Отзывы: