Operating instructions SATA air check set
Note!
When testing a compressed air filter, insert the air check set directly at
the filter output without any additional hose adapter, or only use adapt
-
ers that are absolutely free of any residues.
A pulsation test produces even better results. Here a spray gun is con-
nected parallel to the air check set and triggered repeatedly.
8.1. Preparation: insert test membrane in air check set
Note!
The test membranes (10 each) are supplied packed in a plastic capsule.
The plastic capsule contains:
■
white, flexible test membranes (10 each)
■
blue separators between the individual test membranes
■
robust white plastic discs
■
foam disk (approx. 3 mm thick)
The blue separators, white plastic discs and the foam discs serve mean-
ly to separate and protect the test membranes.
Only use the white, flexible test membranes for the test.
■
Unscrew bottom part
[3-2]
from air check set
[3-1]
.
■
Remove O-ring
[2-1]
.
■
If necessary, remove and discard old test membrane
[1-3]
.
■ Remove sintered filter
[1-1]
.
■ When soiled, clean air check set, sintered filter and bottom part with
clean cleaning agent (see chapter 8.4).
■ Insert sintered filter in bottom part.
■
Using the tweezers
[1-4]
, carefully place the test membrane on the
sintered filter.
■
Using the tweezers, carefully place the O-ring on the test membrane.
■ Screw the bottom part firmly in the air check set.
■
Completely close the compressed air pressure button
[4-3]
by turning it
clockwise.