![Saswell SAS6000UTK-7 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/saswell/sas6000utk-7/sas6000utk-7_installation-and-operation-instructions-manual_1199948007.webp)
- 7 -
【
1
】
Power supply
【
2
】
Remove jumper for 2-transformer system
【
3
】
Optional 24VAC common connection
【
4
】
Common connection must come from cooling transformer
【
5
】
If L terminal is used, 24VAC common (terminal C) must be connected
【
6
】
Install field jumper between Aux and E terminals if there is no emergency heat relay
CONFIGURATION MENU
The configuration menu allows you to set certain thermostat operating characteristics to your system
or personal requirements.
To enter the configuration menu, switch off the thermostat
1) Press
MENU
for displaying main menu button, Press
OTHER
for display other menu button
Press system
until
OFF
blink
Press
DONE
to save changes
Press
MENU
for displaying main
menu button
Press
OTHER
for displaying other
menu button