Saswell SAS6000UTK-7 Скачать руководство пользователя страница 17

 

 

- 17 - 

 

Adjust program schedules 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press 

MENU

 button to display main menu 

button. Press 

SET SCHED

 to enter set 

program mode. 

 

 

 

 

 

 

Select days to set program schedule. It can be 

a single day of the week or a group of days of 

the week 

 

Select 

HEAT

 or 

COOL

 for program setting 

by pressing system button. 

 

To view preset schedule, press 

VIEW 

SCHED

 button. 

 

 

 

Select 4 different time period for setting 

program schedule. 

WAKE, LEAVE, 

RETURN, SLEEP. 

When viewing the program, you can view 

the preset program schedule by selecting the 

day and the time period.   

 

 

 

Adjust time and set temperature for 

selected time period by pressing 

or

 

 

Press 

DONE

 to save and exit (or press 

CANCEL

 to exit without saving changes) 

 

Press 

RESET

 and confirm by 

DONE

 to 

resume to factory default program schedule 

setting. 

Press 

SET SCHED

to set program

Содержание SAS6000UTK-7

Страница 1: ...Auto change over Permanent user setting retention during power loss no batteries are required Optional 7 day programming and non programmable Optional temperature display of Celsius or Fahrenheit sca...

Страница 2: ...rmostat Home Screen Description Figure 2 Figure 1 Time of the day System Switch Fan Swtich Menu key for entering different modes Date of Week Set Temperature Room Temperature Temperature Up Down used...

Страница 3: ...s CLEAN DISPLAY for entering 30 second count back time for cleaning the display Press PREVIOUS STEP for going back to last configuration menu item 9 Press SET SCHED for setting schedule for each days...

Страница 4: ...xpired INSTALLATION 1 Pull the thermostat body off the thermostat base Forcing or prying on the thermostat will cause damage to the unit 2 Place base over hole in wall and mark mounting hole locations...

Страница 5: ...y Y Compressor contactor G Fan relay C S1 24VAC common remote sensor 3 4 S2 Remote sensor RC Power 1 RH RH RC joined by jumper W Heat Relay Y Compressor contactor G Fan relay C S1 24VAC common remote...

Страница 6: ...ing B Changeover valve energized in cooling G Fan relay C S1 24VAC common remote sensor 3 S2 Remote sensor L Equipment monitor 5 RC Power 1 RH RH RC joined by jumper Y1 Compressor relay 1 E Emergency...

Страница 7: ...there is no emergency heat relay CONFIGURATION MENU The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements To enter the configur...

Страница 8: ...T STEP AUMOdE HA HA HE HA Fossil fuel backup heat HE Electric backup heat NA NA 5 NEXT STEP CHANGE 0 0 1 0 Manual changeover 1 Auto changeover 6 NEXT STEP DbaNd 3 2 3 4 5 6 7 8 9 Auto changeover dead...

Страница 9: ...elect second stage cooling rate 18 NEXT STEP FILTER 00 00 12 Select filter replacement run time 19 NEXT STEP UVLAMP UF UO or UF Select UV lamp replacement run time 20 NEXT STEP CLOCK 12 24 12 Selectio...

Страница 10: ...ecovery operation The thermostat has an intelligent recovery function that brings your room temperature to the set temperature at exactly the pre set time by turning on the heating earlier Select ON t...

Страница 11: ...1 HP2 2H setting in system type option Second stage heating rate Second stage heating will activate Hcycle H2sp below first stage heating 16 Select second stage cooling rate This option apply only to...

Страница 12: ...en remote sensor option menu item 20 is set 2 0 No heat pump compressor lockout 15 20 25 30 35 40 heat pump compressor lockout temperature With fossil fuel backup See menu item 3 Auxiliary heat type o...

Страница 13: ...onal air cleaning Choose the System Setting Cool Off Heat Emer Auto Press the SYSTEM button to select Heat Thermostat controls only the heating system Cool Thermostat controls only the cooling system...

Страница 14: ...am schedule What ever temperature you set will be maintained 24 hours a day until you manually change it or press RUN SCHED to cancel Hold and resume the program schedule Vacation Hold Override This f...

Страница 15: ...set to 1 or 2 INFO will display in home screen Press INFO for inquiring outside temperature Thermostat will display outside temperature Inquiry for filter count back time This operation is only avail...

Страница 16: ...e configuration menu item 6 Intelligent Recovery operation Compressor protection See configuration menu item 10 Select compressor lockout delay Heat Pump Temperature Lockout See configuration menu ite...

Страница 17: ...reset schedule press VIEW SCHED button Select 4 different time period for setting program schedule WAKE LEAVE RETURN SLEEP When viewing the program you can view the preset program schedule by selectin...

Страница 18: ...rogram The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures Keep the following guidelines in mind when planning your program In Heating lower...

Страница 19: ...19 CUSTOMER ASSISTANCE After reading this guide if you have any question about the operation of your thermostat please contact your installer or service provider...

Страница 20: ...20...

Отзывы: